manualshive.com logo in svg
background image

6-041222 X2 

1

212w Wiring Diagrams

PRINTER’S INSTRUCTIONS:

LIT 212W WIRING INSTRUCTIONS - P/N: 6-041222 X2 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: FLAT 17.000” X 11.000” FOLDED 8.500” X 11.000” - TOLERANCE: ± .125” - SCALE: 1-1

TECHNICAL NOTES

This product was re-designed using a new manufacturing 
technology, which changed the physical appearance of 
the keypad electronics. Also, the voltage selection jumper 
on the main circuit board is no longer required.

To prevent electrical kick back voltage from damaging the 
keypad, when using an electrical locking device, you MUST 
install the transorb as close as possible to the lock. Wire the 
transorb in parallel with the lock power terminals.

Also, to avoid ESD (electro-static discharge) from interfering 
with the operation of the keypad, ground the negative terminal 
of the keypad to earth ground. If you cannot ground the power 
supply, then you must ground the keypad housing.

The manufacturer recommends using a fi ltered and 
regulated power supply.

When mounting the 212w outside, use a weatherproof back 
box and apply silicone to the area where the wires enter the 
case. Also, provide a weep hole at the bottom of the back box 
to prevent condensation from collecting on the circuit board.  
This keypad is not for use in extreme weather conditions; 
please consult the factory for additional keypad models.

SPECIFICATIONS:

MECHANICAL:

BOARD DIMENSIONS: 1.80”W x 2.555”H x 1.125”D

ELECTRICAL:

 VOLTAGE:  12-24 

Volts 

AC/DC 

(No Jumper Required)

 CURRENT:  8mA@12VDC typical; 
 

 

 

35ma with relay energized.

  

16mA@24VDC 

typical; 

 

 

 

45ma with relay energized.

  

21mA@12VAC 

typical;

 

 

 

74mA with relay energized.

  

43mA@24VAC 

typical;

 

 

 

91mA with relay energized.

 

Note: 

Keypads using the 293 Relay Board,

 

 

need an additional 30mA for each

  

relay 

energized.

  OUTPUTS: 

Main Relay: 5 Amp, Form C @ 24VDC

 

 

with 10 Amp surge.

 

 

Outputs 2, 3, and 4 are 50mA negative

  

voltage 

outputs

ENVIRONMENTAL:

TEMPERATURE: -20°F TO 130°F (-28°C TO 54°C)
Weather Resistant

TECHNICAL SUPPORT

DEALERS/INSTALLERS ONLY! End users must contact 
the dealer/installer for support. If the keypad still does 
not work after troubleshooting, please call the Technical 
Services department at 1-800-421-1587.

• Packing Checklist

212w Keypad
10 Conductor Wire Harness (1)
4 Conductor Wire Harness (1)
Slotted screws (2)
Security Screws (2)
Transorb (1)
Mounting Gasket (1)
Features & Programming Guide
Warranty Guide

212w Keypad 

Wiring Diagrams & Specifi cations

Note: This product is designed to be installed and serviced

by security and lock industry professionals.