Installation Instructions
Positioning module
Conductor rail program 0832, C-rail,
Console, ProShell
MV0800-0015a-EN
www.conductix.com
translated document
Page 9 of 23
3
C-rail
3.1
Structure and product description
The positioning module in the "C-rail" variant consists of the following components:
Item
Name
Order No.
Note
1
Positioning band profile
08-3130467 (with affixed positioning
band)
08-3130466 (without affixed posi-
tioning band)
Separate positioning bands for affixing:
08-3198189
08-3053615
2
Band holder
08-H016-0267
3, 4
Clamping unit with holding plate
08-S008-0305
Fig. 12: C-rail
3.2
Installation
ATTENTION!
The positioning band profile must be free of excessive tension!
When mounting and tensioning the tensioning unit with a holding plate, no waves may arise in
the positioning band profile.
The distance between the band holders should be between 500 and 1000 mm. The band holders should be positioned in such a way
that they do not move during operation. Two installation variants are possible:
Inserting/clipping the positioning band profile into the preassembled band holders
Mounting the band holders with positioning band profile already inserted/clipped
2
1
3
4