60 | Troubleshooting
2588787_B_EN_2005_US_OM
US
Drain fault
Probable Cause
Corrective Action
"Drain fault" appears when the permissible draining time has been exceeded and the sensors still detect a
water in the reservoir.
Drain line clogged
n
Clean the drain line.
Clogged or defective drain valve
n
Clean the drain valve. Replace the drain valve if necessary.
Water level sensor stuck
n
Clean the water level sensor inside the reservoir.
Blower pack fault
Probable Cause
Corrective Action
Blower pack not connected or installed
n
Disable the Ultrasonic Blower Pack. Refer to
.
Blower pack defective
n
Consult the Ultrasonic Blower Pack manual.
High temperature
Probable Cause
Corrective Action
Ambient temperature too high
n
Check if the ambient temperature is within operating range.
Refer to
Fan failure
Probable Cause
Corrective Action
Blower fan blocked
n
Clean the fan. Refer to
.
Blower fan defective
n
Replace the blower fan inside the reservoir.