TPHF017/1101
FEATURES
One Conair Drive
●
Pittsburgh, PA 15202
●
412-312-6000
●
FAX 412-312-6227
●
www.conairnet.com
TEMPERATURE CONTROL UNITS
Thermolator® vacuTrac (VTR1-DI and VTR2-D2)
Positive/Negative Temperature Controller
FEATURES
Expansion/fluid reservoir
accepts thermal expansion
of fluid when heated.
High efficiency pump
pushes fluid through
the system.
Air/water separation
tank allows entrapped
air to escape to the
expansion tank.
Pressure relief valve
prevents system
over pressurization.
Venting line prevents
trapped air in system.
Cooling check valve
prevents coolant back
flow into the vacuTrac.
Level switches
control tank fluid level.
Make-up solenoid valve
maintains tank level.
Cooling solenoid valve
lets hot fluid out of system.
Vacuum generating jet
pump/venturi
To process
pressure gauge
Three-way ball valve
diverts flow to
generate vaccuum.
From process
pressure gauge
Overflow connection
relieves system static
pressure.
Cooling water outlet
Cooling water inlet
From Process
From Process
Pressure Gauge
Cooling In
and Make-Up
Manual Three-Way
Ball Valve
To Process
Pressure Gauge
To Process
Cooling Out
Process Piping
Cooling Water/Make-Up Piping
Make-Up Solenoid
Valve
3 Gallon
Reservoir
Vent and Overflow
Connection
Make-Up Switch
Low Level Switch
Union
Air/Water
Separation
Tank
Return
Temperature
Thermocouple
Pressure
Relief
Valve
Heater Tank
(9 or 12 kW)
Pump
Drain
Drain
Cooling
Solenoid
Valve
Check
Valve
Supply
Temperature
Thermocouple
Air
Vent
Line
Union
Jet Pump/
Venturi
Note:
Maximum Set
Point is 180
°
F
Positive/negative pressure
units use a jet pump/venturi to
produce negative pressure in
the “from process” lines.
Water at positive pressure
will leak out of mold cracks or
bad o-rings. During negative
pressure operation, however,
air is drawn through the lines,
and the mold operates without
leaking. A manual three-way
ball valve can be closed to
make these units into stan-
dard direct injection units.
Because the units use water
and vent to the atmosphere,
they have a maximum process
temperature of 180° F.
Summary of Contents for Thermolater vacuTrac