S
PECIFICATIONS
UGH015/0100
Thermolator TW-1 and TW-2
D
ESCRIPTION
2-7
TW1
TW2
Zones
(1, 2 or 3)
Direct Injection (DI)
Closed Circuit (CC)
Isolated Circuit (IC)
PERFORMANCE CHARACTERISTICS
-
*Lower operating temperatures can be obtained with larger cooling valves. Consult your Conair representative.
Models
TW1 -DI or TW2 -DI
TW1 -CC or TW2 -CC
TW1 -IC or TW2 -IC
Minimum Setpoint Temperature °F {°C}
32 {0}
32 {0}
32 {0}
Maximum Setpoint Temperature °F {°C}
250 {121}
250 {121}
180 {82}
Minimum Operating Temperature °F {°C}
Approximately 20° {11°} above the cooling water inlet temperature*
Standard Cooling Valve Size inches {mm}
1/4 {6.35}
3/4 {19.05}
3/4 {19.05}
Available pump sizes
0.75, 1, 2, 3, 5 or 7.5 Hp {0.56, 0.75, 1.49, 2.24, 3.73 or 5.59 kW}
Available heater sizes
9, 12, 18, 24, 36 or 48 kW
9, 12, 18 or 24 kW
PUMP PERFORMANCE
-
Consult your Conair representative for pump performance characteristics at other operating points.
Pump
3/4 HP {0.56 kW}
1 HP {0.75 kW}
2 HP {1.49 kW}
3 HP {2.24 kW}
5 HP {3.73 kW}
7.5 HP {5.59 kW}
Nominal Flow gpm {lpm}
40 {151}
45 {170}
55 {208}
80 {303}
100 {379}
115 {435}
Pressure@ Nominal Flow psi {kg/cm
2
}
17 {1.2}
18 {1.3}
31 {2.2}
35 {2.5}
43 {3}
51 {3.6}
TOTAL FULL LOAD AMPS PER ZONE
All voltages are 3 phase, 60 Hz.
Heater
9 kW
12 kW
18 kW
24 kW
36 kW
48 kW
Voltage
208V 230V 460V 575V 208V 230V 460V 575V 208V 230V 460V 575V 208V 230V 460V 575V
Pump
0.75 HP {0.56 kW}
28.9 26.2 13.1 10.5 37.3 33.8 16.9 13.5 54.0 48.8 24.4 19.5 70.7 64.0 32 25.6
1 HP
{0.75 kW}
29.4 26.6 13.3 10.6 37.8 34.2 17.1 13.7 54.4 49.2 24.6 19.7 71.2 64.4 32.2 25.8
2 HP
{1.49 kW}
31.8 28.8 14.4 11.5 40.2 36.4 18.2 14.6 56.8 51.4 25.7 20.6 73.6 66.6 33.3 26.6
3 HP
{2.24 kW}
34.7 31.4 15.7 12.6 43.1 39.0 19.5 15.6 59.7 54.0 27.0 21.6 76.5 69.2 34.6 27.7
5 HP
{3.73 kW}
38.5 34.8 17.4 13.9 46.9 42.4 21.2 17.0 63.4 57.4 28.7
23
80.2 72.6 36.3 29.0
7.5 HP {5.59 kW}
45.7 41.4 20.7 16.6 54.1 49.0 24.5 19.6 70.7 64.0 32.0 25.6 87.5 79.2 39.6 31.7
SHIPPING WEIGHT RANGES
lbs {kg} Weights vary depending on cabinet size and cooling type (DI, CC or IC).
Single Zone
2 Zone
3 Zone
Pump
Min
Max
Min
Max
Min
Max
0.75 HP {0.56 kW}
240 {109}
300 {136}
480 {218}
600 {272}
720 {327}
840 {381}
1 HP
{0.75 kW}
240 {109}
300 {136}
480 {218}
600 {272}
720 {327}
840 {381}
2 HP
{1.49 kW}
250 {113}
310 {141}
500 {226}
620 {282}
750 {336}
870 {396}
3 HP
{2.24 kW}
260 {118}
320 {145}
520 {236}
640 {290}
780 {354}
900 {408}
5 HP
{3.73 kW}
270 {122}
330 {150}
540 {244}
660 {300}
810 {366}
930 {423}
7.5 HP
{5.59 kW}
280 {127}
340 {154}
560 {254}
680 {308}
840 {381}
960 {435}
DIMENSIONS
in. {mm}
Cabinet Style
A
B
C
D
E
Height
28.0 {710}
28.0 {710}
28.0 {710}
43.0 {1090}
43.0 {1090}
Depth
22.5 {570}
22.5 {570}
22.5 {570}
31.5 {800}
31.5 {800}
Width
13.75 {350}
27.5 {700}
41.25 {1050}
14.0 {355}
28.0 {710}
208V 230V 460V 575V 208V 230V 460V 575V
104.0 94.0 47.0 37.6 137.0 124.0 62.1 49.7
104.3 94.4 47.2 37.8 137.7 124.6 62.3 49.6
106.7 96.6 48.3 38.6 140 126.8 63.4 50.7
109.6 99.2 49.6 39.7 143 129.4 64.7 51.8
113.4 102.6 51.3 41.0 146.7 132.8 66.4 53.1
120.7 109.2 54.6 43.7 154 139.4 69.7 55.8
MODEL DESIGNATIONS
TOTAL FULL LOAD AMPS PER ZONE
All voltages are 3 phase, 60 Hz.
Heater
0 heaters
Voltage
208V 230V 460V 575V
Pump
0.75 HP {0.56 kW}
3.9
3.6
2.3
1.5
1 HP
{0.75 kW}
4.4
4.0
2.5
1.6
2 HP
{1.49 kW}
6.8
6.2
3.6
2.5
3 HP
{2.24 kW}
9.7
8.8
4.9
3.6
5 HP
{3.73 kW}
13.5 12.2 6.6
4.9
7.5 HP {5.59 kW}
20.7 18.8 9.9
7.6
NOTE:
Thermolators
can be ordered
without heaters for
certain applications.
Summary of Contents for Thermolater vacuTrac
Page 9: ...Figure 1...
Page 12: ......
Page 15: ......
Page 16: ......
Page 50: ......
Page 62: ......
Page 100: ......
Page 106: ......
Page 117: ...UGH015 0100 TW 1 230 460V WIRING DIAGRAM PD 5...
Page 119: ...UGH015 0100 TW 2 230 460V WIRING DIAGRAM PD 7 2...