TECHNICAL DATA
Technical data of the thermostats (transmitters):
— temperature measurement range:
5 to 35°C (in 0.1°C increments)
— adjustable temperature range:
5 to 35°C (in 0.5°C increments)
— temperature measurement accuracy:
±0.5°C
— temperature calibration range:
±3°C (in 0.1°C increments)
— selectable switching sensitivity:
±0.1°C; ±0.2°C; ±0.3°C
— storage temperature:
-10°C
to
+40°C
— battery voltage:
2 x 1.5V
ALKALINE
batteries
(LR6
type;
AA
size)
— power consumption:
1.3mW
— battery lifetime:
approx.
1
year
— operating frequency:
868.35MHz
— dimensions:
130 x 80 x 22mm (without holder)
— weight:
112g
— temperature sensor type:
NTC 10kΩ ±1% at 25°C
Technical data of the receiver unit:
— power supply voltage:
230V
AC,
50Hz
— power consumption:
0.3W
— loadability of the relay that controls the boiler:
24V AC/DC to 230V AC, 50Hz,
6A
(1A
inductive
load)
— voltage of the zone outputs:
230V AC, 50Hz
— loadability of the zone outputs:
1A (0.5A inductive load)
— transmission distance:
approx. 50m in open terrain
— weight:
210g
Total weight of the device: approx. 550g (2 ther2 1 receiver)
- 19 -