background image

2.2 Setting the current day and time

Press the “

SET

” button to go to the main screen, then press the “

DAY

” button. 

At this time only the first three letters of the current day will flash on the display 

of the thermostat and the hour and minute values can be seen. 
Using the large          and           buttons on the front panel of the device, set the 

the current day (Monday 

MON

; Tuesday 

TUE

; Wednesday 

WED

, etc.). Press 

the “

DAY

” button again. At this time the contraction indicating the day stops 

flashing  and  becomes  visible  continuously  while  the  numbers  indicating  the 

hour will flash on the display. Using the large          and          buttons on the 

front panel of the device, set the hour value of the current time. Press the “

DAY

” 

button again. At this time the numbers that indicate the hour stop flashing and 

become visible continuously, while the numbers indicating the minute will begin 

flashing. Using the large            and           buttons on the front panel of the device, 

set the minute value of the current time.
When you wish to continue modifying the settings, please press the “

DAY

” 

button again. If you wish to finish settings, confirm them by pressing the 

SET

” 

button. At this point adjusted data are recorded and the device goes back to 

the main screen (if no buttons are pressed for at least 15 seconds, the settings 

are automatically confirmed and the device goes back to the main screen).

   

2.3 Switching between the heating and cooling mode

There is a possibility to easily switch between the heating and cooling mode 

of the thermostat. The output terminals of the receiver unit 

No.1 (NO)

 and 

No.2 (COM)

 are closed below the set temperature in heating mode, and they 

are closed above the set temperature in cooling mode (taking the switching 

sensitivity into account). Following the heating/cooling command of the 

thermostat, 230V AC, 50Hz voltage appears on the zone outputs associated 

with the thermostats (

L1-N1

L2-N2

; etc.). The thermostat indicates the 

heating command with the icon      and the cooling command with the       in 

the bottom left corner of the display.

To  switch  between  the  two  modes,  first  press  the 

SET

” button to go to 

the main screen. Then press the “

SET

” button again and hold it down and 

press the “

COPY

” button, too. After this, the notice

 „

 or 

 appears 

in place of the time characters, according to the selected mode. Following 

this, switch between the modes using the large          and          buttons, then 

confirm it by pressing the 

SET

” button (if no buttons are pressed for at least 

15 seconds, the setting is automatically confirmed). After this confirmation, 

the device goes back to the main screen.

2.4 Setting the switching sensitivity (accuracy)

The switching sensitivity means the temperature difference between the 

adjusted value and the actual temperature measured during the switching 

process. A smaller switching sensitivity results in steadier room temperature 

and therefore in higher comfort. The heat loss of the room (building) does 

not depend on the switching sensitivity.

- 5 -

Summary of Contents for Q8RF

Page 1: ...COMPUTHERM Q8RF Multi zone programmable wireless radio frequency digital room thermostat Operating Instructions NEW design...

Page 2: ...g the living room and the bathroom during the day and the bedroom during the night Because there is a wireless radio frequency connection between the thermostats and the receiver no cable is required...

Page 3: ...tual temperature measured during the switching process In case of the 0 2 C switching sensitivity and heating mode for example if the set temperature is 20 C then the device switches the boiler on at...

Page 4: ...ead may disturb the temperature control of the flat 2 PUTTING THE THERMOSTAT INTO OPERATION BASIC SETTINGS 2 1 Inserting batteries Pressing the lock on the upper side of the housing of the thermostat...

Page 5: ...tween the heating and cooling mode There is a possibility to easily switch between the heating and cooling mode of the thermostat The output terminals of the receiver unit No 1 NO and No 2 COM are clo...

Page 6: ...deactivate this function using the large and buttons The notices and indicate activated and deactivated state respectively Finally confirm the setting by pressing the SET button if no buttons are pres...

Page 7: ...ctivate more than one switch for each day Furthermore it is advised that a comfort temperature is used only those times when the room or building is in use since every 1 C decrease of temperature save...

Page 8: ...s should be copied using the COPY button A separate program can be created for the heating and cooling mode and these programs are preserved when switching between the modes Therefore if the thermosta...

Page 9: ...ich is indicated on the display of the device by flashing the temperature value to be set C by default Set the desired temperature using the large and buttons then press the PROG button e Then the sta...

Page 10: ...d the flashing abbreviation MON indicating Monday shows that conditions are ready for copying a program Select the day whose program you wish to copy to another day or other days using the large and b...

Page 11: ...the new program as described in Sections 2 and 3 3 6 Program inspection First press the SET button to go to the main screen then press the PROG button At this point the abbreviation indicating the da...

Page 12: ...program switch Set the required temperature using the large and buttons on the front panel of the device At this time the icon appears on the display indicating that the thermostat is operated with m...

Page 13: ...anual control e g that is 3 days After this time has elapsed the icon disappears and the device resumes the program that has been set If you wish to return to the set program before the time set for t...

Page 14: ...E THERMOSTAT TO ITS FACTORY DEFAULT SETTINGS By pressing the RESET button located on the main panel of the thermostat the thermostat can be reset to its factory default settings This results in deleti...

Page 15: ...onsider the loadability of the receiver unit and follow the manufacturer s instructions of the heating or cooling equipment The device must be installed and connected by a qualified professional The v...

Page 16: ...it depressed for approximately 3 seconds until the red LED light on the receiver stops flashing it remains switched on or off depending on the set and measured temperatures Finally press the SET butt...

Page 17: ...orm the test press the TEST button for approximately 2 seconds Following this the thermostat will send alternating every 5 seconds switch on and switch off control signals to the receiver for 2 minute...

Page 18: ...Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C MONDAY MON SUNDAY SUN SATURDAY SAT FRIDAY FRI THURSDAY THU WEDNESDAY WED T...

Page 19: ...A size power consumption 1 3mW battery lifetime approx 1 year operating frequency 868 35MHz dimensions 130 x 80 x 22mm without holder weight 112g temperature sensor type NTC 10k 1 at 25 C Technical da...

Page 20: ...set the temperature using the and buttons for a period of 1 to 9 hours set the temperature using the and buttons then press the DAY button and finally set the duration using the and buttons for a per...

Reviews: