- 16 -
Cut or break out the outlets to the required connection points at the bottom of
the receiver unit, in order to be able to connect wires to them.
9.2 Putting the receiver unit into operation
Turn on the power supply to the receiver unit. A few seconds after the LED
lights flash once, the receiver unit becomes ready for operation. This state is
indicated by the blue LED light with the "
A/M
" sign. After this, you can start
tuning the receiver and the thermostats together. For this purpose press a
button on the receiver associated with one of the heating zones and keep
it depressed (for approximately 3 seconds) until the red LED light next to
it starts flashing. After this, press the “
SET
” button of the thermostat and
keep it depressed then press the “
DAY
” button of the thermostat and keep it
depressed too (for approximately 10 seconds) until the notice " " appears on
the display. Next, select the same number as the number of the heating zone
selected on the receiver unit using the large
and
buttons. Following
this, press the “
COPY
” button and keep it depressed (for approximately 3
seconds) until the red LED light on the receiver stops flashing (it remains
switched on or off depending on the set and measured temperatures). Finally,
press the “
SET
” button, so that the receiver unit “learns” the safety code of the
transmitter (thermostat). The safety code will not be lost even during a power
outage, the device memorizes it automatically.
After tuned together, the receiver unit receives switching signals from the
thermostats, controls the boiler (or air conditioner) and gives commands
to open/close the heating zone valves (max. 4 zones, loadability of the
zone outputs: 230V AC, max. 1A (0.5A inductive load)) associated with the
thermostats. The receipt of switching signals is indicated by the switched
on or off state of the red LED light associated with the thermostat on the
receiver. By repeating the above steps, tune all of the thermostats and the
receiver together.
ATTENTION!
Pressing the “
SET
” and “
DAY
” buttons simultaneously for 10
seconds and then pressing the "
COPY
" button generates a new safety code
for the thermostat, and the receiver will recognize it only after a repeated
tuning. With this in mind, do not repeat the tuning steps without any reason
after the units have been tuned successfully.