background image

Consumer: Please Read These Instructions And Keep For Your Reference

© 2014 Pinnacle Products International, Inc.

668 Stony Hill Road #302 Yardley, PA 19067 USA Toll Free: (800) 641-6996

Fax: (215) 891-8461 

 Web: www.remingtonheater.com 

 Email: [email protected]

701000307-14

IMPORTANT:

Read and understand all of the directions in this manual before assembling, 

starting, or servicing the heater. Improper use of this heater can cause serious injury. Keep this

manual for future reference.

GENERAL HAZARD WARNING:

Be sure to comply with the instructions and  warnings provided with this heater, or death, 

serious bodily injury and property loss, damage from the hazards of fire, explosion, burn,

asphyxiation, and carbon monoxide poisoning can result.  

Only persons who can follow and understand these instructions should use or service this

heater. If you need heater information such as an instruction manual, labels, etcetera, contact

the manufacturer.

Not for use in residential living areas or in non-adequately ventilated enclosed

spaces.

DANGER

DANGER

For outdoor use. Indoor use permitted for: The temporary heating of adequately 

ventilated buildings or structures under construction, alteration or repair.

Model Number

HH-600T-KFA

User’s Manual & Operating Instructions

Summary of Contents for HH-600T-KFA

Page 1: ...the instructions and warnings provided with this heater or death serious bodily injury and property loss damage from the hazards of fire explosion burn asphyxiation and carbon monoxide poisoning can result Only persons who can follow and understand these instructions should use or service this heater If you need heater information such as an instruction manual labels etcetera contact the manufactu...

Page 2: ...or air pollution Use this heater only in well ventilated areas Provide at least a three square foot 2 800 sq cm opening of outside air for every 100 000 BTU hr of heater rating People with breathing problems should consult a physician before using the heater Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble flu like symptoms such as headaches dizziness and or nausea If yo...

Page 3: ...el storage should be a minimum of 25 ft from heaters torches portable generators or other sources of ignition All fuel storage should be in accordance with federal state or local authorities having jurisdiction Never use this heater in living or sleeping areas NEVER use this heater where flammable vapors may be present Risk of electric shock Use only the electrical power voltage and frequency spec...

Page 4: ...ILE BURN ING OR WHILE CONNECTED TO A POWER SOURCE Assembly Figure 2 Features of HH 600T KFA Front Handle Handle Frame Cord Wrap Rear Handle Screw S Screw L Fuel Tank Flange Nut Wheel Support Frame Bushing Wheel Cap Cotter Pin Flat Washer L Wheel Pneumatic Flat Washer S Axle Wheel Tube Valve Fan Guard ...

Page 5: ...nch needle nose pliers ASSEMBLING FRAME AND WHEELS 1 Slide axle through wheel support frame Install wheel bushings flat washers S and wheel on axle NOTE When installing wheels tube valve should face out from support frame Figure 2 2 Place flat washers L and cotter pins on axle ends and bend cotter pins with long nose pliers to secure 3 Place wheel cap on flat washers L and put wheel cap in flat wa...

Page 6: ...temperature rise to an unsafe level If this device acti vates and turns your heater off it may require service Once the temperature falls below the reset temperature you will be able to start your heater Electrical System Protection This heater s electrical system is protected by a fuse that protects it and other electrical compo nents from damage Fuse is located inside of an in line FUSE BARREL I...

Page 7: ...inue to run during the cooling cycle This allows the fan to cool the combustion chamber When the cooling cycle approx 2 minutes is finished the motor will stop Do not unplug heater until cooling cycle is finished 2 Disconnect heater from power source 3 To temporarily stop heater set thermostat at a temperature lower than air around heater Heater will cycle back on if air temperature around heater ...

Page 8: ...ur heater 3 Reinstall drain bolt as follows Insert bolt s seal head fully into drain hole so that flange is flush to tank s bottom Insert seal cap fully into head hole so that cap flange is flush to head flange IMPORTANT Reinstall bolt fully into hole in tank otherwise it will not seal completely Make sure storage place is free of dust and corrosive fumes Store the heater in the original box with ...

Page 9: ...rmly 40 50 inch pounds 4 5 5 6 N m Reinstall upper shell NOZZLE Remove dirt in nozzle as needed Remove upper shell Remove fuel line B from burner assembly by using wrench Remove burner head from burner assembly Remove lead wire from spark plug Remove spark plug from burner head Carefully remove nozzle from burner head using socket wrench Blow compressed air through face of nozzle This will remove ...

Page 10: ...e Figure 13 Take out fuel filter from fuel tank Wash fuel filter A with clean kerosene Replace fuel filter in fuel tank Replace fuel cap on fuel tank PUMP PRESSURE ADJUSTMENT Remove rear shell Remove fuel line A from fuel pump by using wrench Replace pressure gauge at outlet of fuel pump Adjust pump pressure by turning pressure adjustment screw Replace pressure gauge at outlet of fuel pump Adjust ...

Page 11: ...e gauge and plug in end of filter cover NOTE If heater does not ignite when heater is turned on please turn AIR VENT SCREW counter clockwise to release air then turn OPERATION SWITCH back on 2014 Pinnacle Products International Inc 11 Kerosene User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED TO A POWER SOURCE Maintenance Continued Pump Adjusting Screw Figure 14 Pump Pr...

Page 12: ...2014 Pinnacle Products International Inc 12 Kerosene User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED TO A POWER SOURCE Exploded View Figure 16 Exploded View for HH 600T KFA ...

Page 13: ...01 18 Drain Line 70 036 1001 19 Ignitor 70 037 0800 20 Combustion Chamber 21 Power Cord 70 034 0300 22 Wheel Support Frame 70 064 0200 23 Wheel Axle 70 041 0403 Item Description HH 600T KFA 24 Wheel 70 041 0113 25 Cotter Pin 70 041 0107 26 Wheel Bushing 70 041 0109 27 Flat Washer 70 041 0105 28 Wheel Cap 70 041 0111 29 Safety Guard 70 065 0200 30 Socket Cover 70 030 0100 31 Electric Outlet Assembl...

Page 14: ...n PCB assembly 1 See Pump Pressure Adjustment Page 10 2 See Fuel Filter Page 10 3 See Nozzle Page 9 4 Clean Photocell Lens Page 9 5 Make sure photocell boot is properly seated in bracket See page 10 6 Check electrical components See Wiring Diagrams Page 11 7 Replace Photocell Page 10 1 Fill tank with kerosene 2 See Pump Pressure Adjustment Page 10 3 See Spark Plug Page 9 4 See Fuel Filter Page 10 ...

Page 15: ...nnected Temperature limit safety device is overheated 1 Poor Combustion Flames extending beyond heater Low heat output 2 Power Failure No power supply to heater A Check limit control thermostat B Check sensor connection 1 Wait until unit cools down 1 Poor Combustion Adjust Pump Pressure see page 10 2 Power Failure Check Replace Fuse E4 E5 Other Problems Symptom Possible Cause s Solution ...

Page 16: ...d return the item freight pre paid If Pinnacle Products International Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributo...