background image

31 

  

INSTRUCTION  MANUAL

 

 

     We  thank  you  for  purchasing  our 
product.  Please  read  this  owners 
manual  carefully  before  using  the 
Heater. It is important that you handle 
and use  the Unit according to the in-
structions  to  ensure  its  long  life  and 
to avoid   problems and accidents. Af-
ter  reading  this  guide,  keep  it  for  fu-
ture  reference. 

  INDEX 

Pre-operation Instructions 
 

Special precaution for safety.......................... 34 

  List of parts..................................................... 37 
  Preparation procedures.................................. 41 
    Unpacking.................................................. 41 
    Pre-ignition preparations and checkpoints. 41 
    Fuel to be used .......................................... 42 
    Fuel filling................................................... 44 
    Elevation adjustment.................................. 44 

 
Operating Instructions 

  Ignition ........................................................... 45 
  Turning off...................................................... 46 
  Room temperature adjustment....................... 47 
  Time adjustment............................................. 48 
  Timer operation.............................................. 49 
  Child safety devices ....................................... 50 
 

Maintenance and Others

 

  Some cautions ............................................... 51 
  Maintenance .................................................. 52 
  Regular maintenance  .................................... 54 
  Trouble-shooting  ........................................... 55 
  Parts replacement/ Storage ........................... 58 
  Specifications................................................. 59 
 

DANGER 
NO GASOLINE 

LIQUID  COMBUSTIBLE

 

ONLY 

Summary of Contents for FR 32

Page 1: ...tion Instructions Special precaution for safety 34 List of parts 37 Preparation procedures 41 Unpacking 41 Pre ignition preparations and checkpoints 41 Fuel to be used 42 Fuel filling 44 Elevation adjustment 44 Operating Instructions Ignition 45 Turning off 46 Room temperature adjustment 47 Time adjustment 48 Timer operation 49 Child safety devices 50 Maintenance and Others Some cautions 51 Mainte...

Page 2: ...his would risk causing a failure of the system which is there for your safety p 51 This heater may not be used in rooms which are hermetically sealed such as caravans boats passenger compartments of vehicles etc p 51 Use your heater in a room which is properly ventilated and free of inflammable vapours Each room that the heater is used in must be adequately ventilated the ventilator window must ha...

Page 3: ...en the setting temperature is reached SETTING THE TEMPERATURE MIN OPERATION To set the maximum power of your heater at 800 Watt for SRE3001 FR32 and 1100 Watt for SRE4600 FR46 press MIN switch the MIN lamp will come on You just have to select the temperature with switch and The heater will work at his minimal power whatever the selected temperature or that of the room SET THE TIME To set the time ...

Page 4: ... every hour Lack of oxygen causes imperfect combustion which may cause highly toxic carbon monoxide emissions in the room It is very dangerous DO NOT use the heater in the basement with no ventilation device or rooms with no windows KEEP AWAY any kind of spray cosmetic spray insecticide spray etc that emits flammable gas such as thinners or benzene etc from the blower unit Heated spray containers ...

Page 5: ...ruction may cause fuel leak and fire CAUTION off AVOID locations close to drapes of flammable ma terial DO NOT put laundries sofas too close to the blower unit Flammable material or objects may cause fire DO NOT touch the blower grill while heater is on or immediately after use to avoid fatal burning Keep children away from them Protecting Guard is available as an option CFK RG12 AVOID direct expo...

Page 6: ...ile or a boat in direct sunlight or at the place where the temperature tends to rise quickly in places where gas or chemicals e g freon gas chloride compounds are used such as beauty salons barber shops chemical plants laundries etc at the high locations more than 400 meters above sea level See adjustment Adjustment is necessary before using the heater See Elevation Adjustment Failure to follow an...

Page 7: ...0Hz household use ONLY Fuel tank cover Control panel Indicators Warm air blower Louver Base plate Drain slot Room thermo sensor Power cord Power plug Air intake filter Air intake for combustion Warm air intake Fuel gauge Do not lose it Gasket black Fuel feeder cap Upright position Tank handle Fuel tank 54 Fuel receiver Fuel strainer Fuel filter ...

Page 8: ...ead time back 47 48 49 POWER SELECTOR KEY Use MIN AUTO SAVE for using pur pose respectively 47 ON KEY OPERATION LAMP Use when starting the heater operation The lamp is lit red under operation pre heating The lamp is flashing red buzzer flame is extin guished and the display shows a code error or an alarm 56 45 OFF BUTTON Stops the operation 38 TIMER CONTROL KEY TIMER LAMP For time setting TIMER th...

Page 9: ...SELECTOR KEY Temperature current time timer programmed time can be selected to in dicate ON KEY OPERATION LAMP Use when starting the heater operation The lamp is lit red under operation pre heating The lamp is flashing red buzzer flame is extin guished and the display shows a code error or an alarm OFF BUTTON Stops the operation SWITCH TIMER LAMP For time setting timer on off The lamp is lit timer...

Page 10: ...t 16 Time lamp is light off Indicates current time Timer set time lamp is lit Indicates the pre set time for the timer 56 47 48 49 HEAT POWER LAMP Indicates the heat power se lected Example shows AUTO heat power at the current tempera ture of 20 degrees 47 Indication on Fuel filling Flash Buzzer The unit buzzers and the filling sign lights 30 minutes and 5 minutes before the heater is turned off B...

Page 11: ...lace with high temperature liquid combustible for mobile heater kept in a white polypropylene container or in an uncapped container for long time Always use the proper liquid combustible container Impurified liquid combustible are liquid combustible mixed with even a small amount of any kind of oil gasoline thinner kitchen oil lubricant heavy oil light oil etc liquid combustible mixed with water o...

Page 12: ...n heat rain dust and from other heat sources Liquid combustible for mobile heater which has been stored too long loses its purity and thus its efficiency ADDING LIQUID COMBUSTIBLE FOR MOBILE HEATER When your tank is out of the unit the heater can still be used for a certain period You have to fill your heater When your heater has stopped Or in a room other than the one where the heater is installe...

Page 13: ...er of bad quality has a yellow colour and a acid smell Use up fuel within the season WHAT HAPPENED IF YOU USE BAD LIQUID COMBUSTIBLE FOR MOBILE HEATER Tar form in evaporator and ignition and extinguishment become difficult May cause abnormal combustion and shut off during operation WHAT YOU HAVE TO DO IF YOU INADVERTENTLY USE LIQUID COMBUSTIBLE FOR MOBILE HEATER OF BAD QUALITY Drain the combustibl...

Page 14: ...the safety Avoid hitting the filler cap to be distorted Distorted filler cap may cause liquid combustible leaks Be careful not to drop the tank 4 Replace the tank Carefully replace the filled tank into tank compartment Elevation Adjustment Because the low air pressure makes combustion imperfect it is necessary to adjust the system ac cordingly Adjustment should be done with an electrical socket pl...

Page 15: ...Recoveries Ventilate the room to get fresh air Remove dust on the intake filter Relocate the heater to proper places Unstable flames Cause Stuck fuel flow caused by dirties along pumping system Recovery Stop the operation and consult with local distributor Contact your local distributor or your nearest customer service agent if any other extraordinary flame state is observed NOTES The heater may n...

Page 16: ... during operation Extinguishment will be completed when the odor free lamp goes off and the fan continues to run for about 3 minutes to cool down the Unit TURNING OFF CAUTION NEVER try to extinguish flames by hitting shoving or taking out the plug NOTES Odor free system will not work when flames go out in false extinguishment After ignition your heater will function at full power during 5 minutes ...

Page 17: ...on you can select three modes SAVE AUTO and MINI In SAVE mode The heater automatically stop the operation when the room tempera ture goes up 2 centigrade higher than the setting temperature NOTES Preset temperature may not necessarily be in accordance with the actual temperature indicated on the room thermometer depending on the conditions The room temperature may reach above the programmed temper...

Page 18: ...0 00 then the current time Time figure can be changed from the second press 3 Adjust to the correct time Minutes can be adjusted by one minute at each press Keep the key pressed for a few seconds and the figure will continue to change After the minute reaches 10 figure changes by every ten minutes as shown in the illustra tion Time figures when up I s pressed Press the key one at a time for the mi...

Page 19: ...ch pressing of time key Press the key for a few seconds and the figure will continue to change After the minutes reaches 10 figure changes by every ten minutes Press the key one at a time for minute adjustment 4 Press TIMING key and set the working duration h indicates the combustion goes on without stop 10h indicates 10 hours 9h does 9 hours and 1h does 1 hour of combustion 5 Timer programming is...

Page 20: ...e of power failure caused by earthquakes digital indicator will show E4 and red operation lamp will flash In either case timer lamp is not on Press OFF key then follow the procedure for current time adjustment and timer programming CAUTION Be sure to clear all flammable materials around the heater CHILD SAFETY DEVICES CHILD SAFETY DEVICES Press CHILD SAFETY key for 3 seconds Child safety is indica...

Page 21: ...preserve a minimum clearance of 1 meter from other objects SOME CAUTIONS DO NOT USE YOUR HEATER IN ROOMS SITUATED UNDER THE FLOOR LEVEL AIR SENSOR DETECTOR This heater has been designed with an Air sensor device Abnormal conditions of use of your heater bad ventilation or too small a room will automatically pro voke the shut off of your heater and the Air sensor light will come on IMPORTANT Any ta...

Page 22: ...diately and consult local distribu tor or your nearest customer service agent At Least Once A Week Use soft cloth to clean the Unit body Use a vacuum cleaner to remove dust on the warm air blower louver The warm air blower should be cleaned frequently to avoid burning of dust which may cause unremovable stains on the Unit Diluted domestic chemical detergent on cloth may be effective to the ex trem...

Page 23: ...Unit Remove fuel tank out of the Unit 2 Remove fuel strainer from fuel receiver Be careful not to drop any dust or water onto the receiver 3 Rinse the fuel strainer with clean pure liquid combustible for mobile heater Never rinse it with water 4 Reset the fuel strainer to the Unit Wipe out any oil remaining if any on the receiver before resetting the fuel strainer Replacement of Fuel Filter Fuel f...

Page 24: ... water oil into used newspapers and dispose them If imperfect combustion remains despite of the above procedure contact your local distributor or the nearest customer service agent It is recommendable to conduct the following regular maintenance at least once every two years Every component parts of the Unit goes inferior in quality as time passes It is suggested that regular check up be taken onc...

Page 25: ...requires 1 to 2 minutes of preheating During Combustion Burner head turns red It turns red at minimum heating power It is normal unless there is false ignition or flames accidentally go out Flames glow brilliant reddish orange They usually glow when heated and it is normal This happens especially under the following circum stances The Unit is used in salty air such as near the sea side The Unit is...

Page 26: ...he Unit Combustion Control System has been triggered Earthquakes seismic scale 5 or larger strong impact on the Unit Auto shut off Device has been triggered Overheat inside the Unit Anti overheat device has been triggered Warm air blower louver is blocked resulting overheating All indication lamps are glows Plug is not properly in place Power failure Safety Device has been triggered fan mark lamp ...

Page 27: ...eiver Check that the Unit is placed on flat and even ground surface and that its surrounding is safe Wait till the Unit cools down and clean the warm air intake Remove blocking object if any from the warm air blower louver Remove blocking object if any Plug properly in power outlet Press OFF key first and then ON key after power resumes Ventilate the room and clean the air intake filter Though Com...

Page 28: ... user s liability STORAGE 1 Unplug the Unit 2 Empty fuel tank and fuel receiver Remaining liquid may cause rust or metal erosion 3 Clean the Unit body air intake filter and warm air intake with dry cloth 4 Check every part of the Unit for any damage If any ask for repairment 5 Put the Unit into its box and humidity free storage area Keep it in an up right position never in a tipped position or on ...

Page 29: ...put MAX 3000 4600 Watt Average 1890 2840 MIN 775 1020 Fuel tank capacity L 4 0 L 7 1 L Continuous Combustion Capacity MAX 49 4 h 65 9 h MIN 12 5 h 14 5 h Suitable room size in m MAX 120 MIN 48 184 MIN 72 Unit overall dimensions HxWxD mm 415x400x300 455x500x310 Weight kg 9 2 kg 13 3 kg Voltage and frequency 230V Mono phase 50HZ Rated power consumption W 34 W 40 W Fuse Tube type 6 3 A Safety devices...