Firmware upgrade function
The CDD5.0 door drive firmware can be upgraded, in case new versions are available, using a special usb
stick (refer to paragraph 7.2), that presents two access sides:
Computer access side: USB connector
o
The stick can be connected to any PC that has usb ports: the stick is recognized by the PC as
a mass storage device. Copy the version to be installed on the usb stick and proceed with
the normal operations to remove the stick from the PC.
o
Check that usb stick contains only the version to be installed. In case of multiple versions,
the more recent one will be installed.
Door drive access side: RJ45 connector
o
Connect the stick to the door drive, into the X8 plug. Proceed the with the upgrading
sequence reported in the following table.
STEP
Description
Stick LEDS
Visualization
CDD
Display
Notes
0
Door drive
power off
Off
Off
Press OFF key on the CDD 5.0 front panel
1
Insert usb stick
into X8
Off
Off
2
Door drive
power on
All leds blinking
“- -“
Press ON key on the CDD 5.0 front panel
Initialization phase:
- communication between stick and door drive
- data acquisition from the door drive
- check of available file, compatible with the connected door drive
if this checks are successfully completed the usb stick sets the
programming mode on the door drive
go to step4
if any error happened
step3
3
Initialization
error
RED Led on
“- -“
An error happened during initialization phase:
- there is no communication between stick and door drive
Or
- the stick has not saved any file compatible with the connected door
drive
Or
- the connected door drive is not compatible with the stick
Remove the usb key, check the files and retry
4
Restart request
YELLOW Led
blinking
“- -“
Switch off the door drive by pressing OFF key.
Switch on the door drive by pressing ON key.
step5
5
Initialization
All leds blinking
Off
Communication initialization in programming mode.
step6
6
Firmware
upgrade
GREEN Led
blinking
Off
New firmware download in progress from the usb stick to the door
drive memory.
if the download is completed correctly
step8
if any error occurred
step7
7
Firmware
upgrade failed
RED Led on
Off
The upgrade has failed. The door drive remains in programming
mode. Switch off and on the controller, keeping the usb key
connected; then return to step5.
8
Firmware
upgrade
completed
GREEN Led on
“- -“
The firmware upgrade has completed successfully. Remove the usb
key. Switch off and on the door drive and then check the controller
behaviour.
- Table 22: firmware upgrade sequence using usb Key -
Verify on the web site “