ACom6
43
(12/99)
No Change
The output does not respond to any of the following events.
Camera 1 ... 6
When you select a camera, the output is activated. This allows you, for instance, to
switch on a spot-light to illuminate the scene.
Connection
The status of the output responds to the status of a connection. An existing connection
may for instance be signalled by a control lamp.
Local Input 0 ... 6, Remote Input 0 ... 6
The status of an input is passed on to the output. Example: on activating an input via a
door contact the output will switch on a siren. Inputs and outputs of two ACom-devices
may also be cross-connected to make the switch relays follow the inputs of the other
device. This allows you, for instance, to turn on a spot-light on a remote site by using a
switch in the local control station. Vice versa, an alarm sensor at a remote ACom can
trigger a siren in the control station.
Alarm Sources
Apart from the inputs, internal alarm events (ISDN, modem, video sensor, movement)
can also be used for switching an output.
• Select the required actions for every switch output.
☞
Important
You can make changes when the connection is already operating.
Configuration with CMCtrl