Paging Interface Adapter
19
6.
If
Shift
was not checked on the
Global Setting
page, only shift 1 pager in the
first column will be active. If
Shift
was selected on the
Global Setting
, all the
pager ids will be active.
a.
Pagers for Shift 1 are shown on the 1
st
row .
b.
Pagers for Shift 2 are shown on the 2
nd
row.
c.
Pagers for shift 3 are shown on the 3
rd
row.
7.
Column 2 & 3 are for Pulse 1 and Pulse 2. Pulsing is not available for Non-Voltage
input.
Active message
Pager IDs
7. Pager ID
a. If no pager number is required, the blank must have 7 zeros entered.
b. Protocol selections determine what type of pager IDs are used.
Scope
– 0100800 (7 digits)
TAP
– 100 (3 digits),
WaveWare
– 100(3 digits)
Comp2
–100 (3 digits)
c. Select the Alerts type for each pager ID. Alerts A-D.
8. Select the Repeat and Interval for each contact.
a. Repeat 0 -5 or RUR (repeat until reset)
b. When RUR(repeat until reset) is selected, ESCALATION function is not
available.
c. Interval 2 ,5,10,15,20,30 Minutes, 1 or 2 hours.
9. Select
Save to Zone -
In order to reduce redundant key strokes, you can duplicate your original entry
and then edit the area that requires changing.
a. Enter the zone you are copying in the first blank.
b. Enter the ending zone you want to program.
Ie.. Save to: 2 to 32. This will copy all data from zone 2 to 32.
c. The screen will refresh and display Zone 32 (the last zone number
you entered.
d Select Save to Zone