Programming Contacts for Elapse Time Reports
If the PIA3264 is being connected to a Nurse Call Host system and Elapse Time reports are required,
ensure the room number is used as part of the
Active, Reset, Pulse one
and
Pulse two
message. The
system will compare the time the Zone was activated to the time it was reset. It must have some means
to determine one zone from another. Since the room number may not always be the same as the zone
number, it is recommended to use the room number. It is recommended to use three digit. (001-999).
PROGRAMMING INPUTS
Create Default File
All programming is accomplished on the
Master unit
. The
Slave
only has to have a
Unit ID, IP
Address and
how many contact inputs are available, and if connecting to a Call System that outputs
Pulsing, select the correct Host System. Example
: if four logic cards are installed in the slave, the
selection would be 16 contacts. If you are installing a master and 1 slave, the master has 64 inputs and the
slave has 16. You would Select Master and 1 slave on the Global Setting Screen of the master. On the
Slave you would select S1 and 16 contacts on the Global Setting Screen. When you program the Contact
Screen information you enter the data for
ALL
the input on the master unit, 1-64 and the information for
the inputs on the S1 unit, 65-80.
Voltage Input (Contact Programming Screen)
Start on Zone input #1
1.
Select the Type of inputs. (see page 10 for definition)
a.
Voltage Alert High
b.
Voltage Alert Low
2.
Enter Room No. 001-999 if applicable. If Bed Identifier is used Voltage Input Logic
select A thru E. Be sure to include that identifier in the message Card w/o Fuses
text.
3.
Enter Active Message
This is the message that will be sent to the pager when the zone is activated.
Ie.. Steady Voltage applied or No Voltage
4.
Enter Reset Message
This is the message that will be sent to the pager when the zone is reset.
Example Alarm Panel: Zone1 Alarm Reset or Cancelled
Example Nurse Call System: Room XX Reset, Cancelled, Cleared
5.
If a Host System was Selected from the drop down menu on the Global Setting Screen,
you
MUST
check Pulse 1 or Pulse 2 or both for the correct message to be sent to the
Pager when a slow or fast pulse is detected.
a.
AiPhone
b.
Cornell
c.
Dukane
d. Engineered Electronics
e. Heritage MedCall
f. TekTone
Summary of Contents for PIA3264
Page 1: ...Paging Interface Adapter Model PIA3264 Revision 2 3 4 ...
Page 35: ...Paging Interface Adapter 35 Cornell Continue ...
Page 36: ...Paging Interface Adapter 36 Engineered Electronics ...
Page 37: ...Paging Interface Adapter 37 Heritage MedCall ...
Page 38: ...Paging Interface Adapter 38 ...