Table 6-2
Fault Symptom Codes
continued
FSC
Message
Description
6012
Status Unexpected
The Master inter-module process
received a Status packet, but no
Command is currently active.
6013
Invalid Com Blk Type
The Master inter-module process
received a packet from a Slave inter-
module process, but the packet’s
CommBlock type was invalid.
6014
Invalid Com Blk Type
The Master inter-module process
received a packet from the
Command/Message queue, but the
packet’s CommBlock type was invalid.
6015
Ack Timeout - Out
The Master inter-module process
attempted to initiate a packet
transmission to a Slave inter-module
process, but a timeout occurred
waiting for the Slave’s acknowledge.
6016
Ack Timeout - In
The Master inter-module process
attempted to initiate a packet
transmission from a Slave inter-
module process, but a timeout
occurred waiting for the Slave’s
acknowledge.
6017
Ack Invalid - Out
The Master inter-module process
attempted to initiate a packet
transmission to a Slave inter-module
process, but the Slave’s acknowledge
was invalid.
continued