Removal and Replacement Procedures
NAS B2000 Maintenance and Service Guide
2-5
COMPAQ CONFIDENTIAL
Codename: Collins Part Number: 292280-001 Last Saved On: 5/30/02 11:58 AM
3.
After performing the maintenance procedure, slide the device back into the rack:
a.
Press the device rail-release latches.
b.
Slide the device fully into the rack.
c.
Secure the device by tightening the thumbscrews.
Powering Down the Device
System power in the StorageWorks NAS B2000 does not completely shut off with the front
panel Power On/Standby button. The button toggles between on and standby modes, rather
than on and off. The standby position removes power from most electronics and the drives,
but portions of the power supply and some internal circuitry remain active. To completely
remove all power from the system, you must disconnect all power cords from the device.
WARNING:
To reduce the risk of injury from electrical shock,
remove the power cords to completely disconnect power
from the system.
CAUTION:
Electrostatic discharge can damage electronic components. Be
sure you are properly grounded before beginning any installation procedure.
For more information, see the “Electrostatic Discharge” section in this chapter.
To power down the device:
1.
Back up your device data.
2.
Shut down the operating system as directed in your operating system instructions.
3.
Press the front unit identification LED switch on the device front panel to illuminate the
LED. The rear unit identification LED switch illuminates on the device rear panel.
4.
Press the device Power On/Standby button to place the device in standby mode. The
system power LED turns to amber when standby power mode is activated.