Connectors, LED Indicators, Switches, and Jumpers
4-17
Table 4-9
System LEDs and Internal Health LED Status Combinations
continued
System LED and Color
Internal Health
LED Color
Status
Red
■
Interleaving error: DIMM is missing from the
bank, and no valid memory exists in another
bank.
■
Interleaving error: DIMMs are mismatched within
the bank, and no valid memory exists in another
bank.
DIMM failure, all slots in
one bank (Amber)
Amber
■
DIMMs have failed over to the online spare bank.
■
Interleaving error: DIMM is missing from the
bank, but valid memory exists in another bank.
■
Interleaving error: DIMMs are mismatched within
the bank, but valid memory exists in another
bank.
DIMM failure, all slots in
all banks (Amber)
Red
No valid or usable memory is installed in the system.
Overtemperature (Amber)
Red
■
System has reached the operating system
cautionary level.
■
System has exceeded the hardware critical level.
Riser/SCSI interlock failure
(Amber)
Red
PCI riser or Smart Array 5i Controller is unseated. *
Power converter module
(Amber)
Red
The power converter module has failed.
Red
A primary fan has failed at least one zone.
Fan (Amber)
Amber
A redundant fan has failed at least one zone.
Note:
* When the SCSI interlock disable switch is set to default (off), the riser/SCSI interlock failure LED
indicates that the PCI riser or the Smart Array 5i Controller is unseated. If the default setting is changed for