2-6
Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide
5.
At the rear of the server, locate the illuminated rear unit identification LED switch that
identifies the server you are servicing.
Figure 2-3. Rear unit identification LED switch
6.
Disconnect all power cords.
7.
Disconnect all remaining cables on the server rear panel.
Removing the Server from the Rack
To remove the server from your Compaq, Telco, or third-party rack:
1.
Power down the server. See the “Powering Down the Server” section in this chapter.
2.
Loosen the front panel thumbscrews that secure the server faceplate to the front of the
rack.
3.
Remove the server from the rack. Refer to the setup and installation guide or the
documentation that ships with your rack-mounting option.
4.
Place the server on a sturdy, level surface.
Hot-Plug Procedures
You can perform some service procedures as hot-plug procedures without powering down the
server. Before performing hot-plug procedures, observe the following guidelines:
■
For hot-plug fan procedures, ensure that the fan zone is fully populated.
■
For hot-plug power supply procedures, ensure that a redundant power supply is installed
and connected to a power source.