![Compaq 6400R - ProLiant - 1 GB RAM Setup And Installation Manual Download Page 80](http://html1.mh-extra.com/html/compaq/6400r-proliant-1-gb-ram/6400r-proliant-1-gb-ram_setup-and-installation-manual_2645493080.webp)
Installing Hardware Options
3-27
Compaq Confidential – Need to Know Required
Writer:
Gilbert Saldivar
Project:
Compaq ProLiant 6400R Setup and Installation Guide
Comments:
Part Number:
388776-002
File Name:
d-ch03 Installing Hardware Options
Last Saved On:
3/20/00 12:17 PM
Power Supply LEDs
For power supply status, note the color of the power supply LEDs, located on
the front of the power supply.
Table 3-8
Hot-Plug Power Supply LEDs
LED Location
Indicator
Description
Bottom
Green
AC present
Bottom
Off
AC not present or fault
Top
Green
Power Supply OK
Top
Off
Fault
Removing a Hot-Plug Power Supply
1.
Grasp the power supply handle and press up on the thumb latch
.
2.
Pull the power supply out
.
A
B
2
1
1
Figure 3-24. Removing a hot-plug power supply
If you remove and replace a power supply in a redundant hot-plug power
supply configuration while the system is operating, follow these instructions to
prevent a false notification. After removing the hot-plug power supply, wait
for at least 6 seconds before inserting the replacement power supply.