INS_RL1000GW_REV– 15 Jul 2016 PAGE 85
INSTALLATION AND OPERATION MANUAL
RL1000GW
TECH SUPPORT: 1.888.678.9427
+ local-end-point
- create [slot <1>] {port <1-2>} {service-id <1-100>} {position <master| slave>} [protocol
<any>] [application {serial-tunnel |terminal-server |iec101-gw |modbus-gw}] [buffer-mode
{byte| frame}]
[iec101-link-address <0-65535>] [iec101-link-address-len (2,<1|2>]
[iec101-originator-address {none| present}] [unit-id-len (2,<1|2>] [unit-id <0-65535>]
- remove [slot <1>] {port <1-2>} {service-id <1-100>}
-
show
+ tunnel settings
- update low-border-ip-port (9849, <1025- 65434>)
-
show
+ remote-end-point
- create {remote-address <A.B.C.D>} {service-id <1-100>} {position <master| slave>}
[buffer-mode {byte| frame}] [connection-mode [<udp| tcp>]
- remove {remote-address < A.B.C.D>} {service-id <1-100>}
-
show
Serial Commands Description
Command
Description
Serial
Access serial configuration hierarchy. Configuration for ports, local-end-point, and remote-
end-point are available here.
Service show
Provides configuration state of a serial service
local-end-point filter show
Provides detailed configuration state of an iec101 serial tunneling service
card
Auto-recover: allows automatic recovery when identifying continuous loss of serial
infrastructure keep alive (between the serial processor and the Ethernet processor).
Enable: auto recovery will reboot the process.
Disable: no action taken.
Show : show state
Show : display the version and the provision state of the serial processor
port slot 1 port <>
Create/update the serial port
Clear counters
Clear counters