poor performance and safety hazards.

CAT NO.

MODEL

DESCRIPTION

BLOWER ACCESSORY KIT

Manual variable control and automatic thermostat variable control. A blower will increase 

air flow to assist heat distribution from the firebox.

F1086

GA3750A

Manual Fan, Variable Speed

DUPLEX OUTLET KIT

For built-in installation when accessory blowers are used.

(Not Shown)

J1284

GA3555

Kit Outlet

GAS APPLIANCE INSTALLATION KIT

(Not Shown)

F0249

CIKA

Installation Kit

PERIMETER TRIM KIT

F1039

PT32

32" Perimeter Trim Kit - Black

F1041

PT32P

32" Perimeter Trim Kit - Platinum

FIREBOX LINER KITS - HFL300 Series

Ceramic fiber firebox liner adds the look of real brick.

(Not Shown)

J1476

HFL300

Firebrick Liner, Stacked Brick Pattern Off White

J1478

HFL310

Firebrick Liner, Herringbone Pattern, Off White

Summary of Contents for Westerly32ZMN

Page 1: ...ustion and Ventilation section on Page 6 of this manual PFS US Report No F09 121 P900568 00 Westerly32ZMN Westerly32ZMP Vent Free Remote Control Gas Fireplace System WARNING If the information in this...

Page 2: ...y and completely before trying to assemble operate or ser vicethisheater Improperuseofthisheatercancause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisonin...

Page 3: ...material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Fireplaces become very hot when running fireplace WARNI...

Page 4: ...and Maintenance Page 2 9 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these prod ucts may create a white powder residue within burner...

Page 5: ...Lift the carton off the heater Remove packing NOTE The hood is located in the packing on the right hand side of the heater front Lift the heater off the bottom tray 2 Locate two screws above top corn...

Page 6: ...ed or unconfined space The standard method defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all applian...

Page 7: ...remove door to adjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower...

Page 8: ...curtains furniture clothing or other flam mable objects are less than 36 from the front and 42 topoffireplace ForsideclearancesseeFigure 8 Page 9 in high traffic areas in windy or drafty areas CAUTION...

Page 9: ...es of trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes in cab...

Page 10: ...place see Figure 9 Make sure to locate access hole so cabinet mantel will cover it when installed NOTE You can secure base to floor using wood screws Countersink screw heads and putty over 5 Route fle...

Page 11: ...in Corner Figure 14 Connecting Duplex Outlet Blower Support Bracket Cable from Electrical Source Duplex Outlet Screw Blower Power Cord Strain Relief Fitting INSTALLATION Continued 2 If using blower i...

Page 12: ...such as shelves window sills fireplace mantels etc above the appliance NOTICE If your installation does not meet the mini mum clearances shown you must do one of the fol lowing raise the mantel to an...

Page 13: ...f valve test gauge connection sediment trap optional tee joint pipe wrench approved flexible gas line with gas connector if allowed by local codes not provided An equipment shutoff valve with 1 8 NPT...

Page 14: ...iver module see Figure 20 3 Remove screws that attach log base assembly to fireplace see Figure 20 Carefully lift up log base assembly and remove from fireplace see Figure 20 NOTE If adding the HFL300...

Page 15: ...g propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Checkalljointsfromgasmetertoequipmentshutoffvalveforn...

Page 16: ...ater base assembly The data plates contain important warranty and safety information WARNING Failure to position the parts in accor dance with these diagrams or failure to use only parts specifically...

Page 17: ...receiver must be completed INSTALLATION Continued WARNING Make sure your selector switch is in OFF position before installing or changing batteries in your hand held remote or receiver INSTALLING BAT...

Page 18: ...ing heater NOTICE Duringinitialoperationofnewheater burning logs will give off a paper burning smell Open damper orwindowtoventsmell Thiswillonlylastafewhours NOTE Homeowners generally prefer to opera...

Page 19: ...can set your hand held remote control to display the temperature in either Fahrenheit or Celsius With remote control off press Ther mostat button and Mode button at the same time This will toggle the...

Page 20: ...in the room To activate press THERMOSTAT button on remote control see Figure 37 The word ON will appear to the right of temperature bulb graphic on display see Figure 39 Use UP DOWN arrow button to se...

Page 21: ...mote and the receiver will beep 4 times to confirm it receives commands from the new remote SMART MAX Figure 40 Smart Thermostat Setting ON Figure 41 Child Safety Lock Out ON REMOTE OFF PRG To Program...

Page 22: ...ed air holes will create soot Figure 45 Correct Burner Flame Pattern Figure 46 Incorrect Burner Flame Pattern Yellow Tipping Pilot Burner Thermocouple Natural Gas Pilot Propane LP Gas Pilot Thermocoup...

Page 23: ...can you could damage the pilot assembly 1 Shut off unit including pilot Allow unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust a...

Page 24: ...gas lines when installed 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to...

Page 25: ...r a few hours of operation Moisture condensation noticed on windows 1 Not enough combustion ventilation air 1 Refer to Air for Combustion and Ventilation requirements Page 6 Heater produces a whistlin...

Page 26: ...ecking Gas Connections Page 14 Fireplace shuts off in use ODS operates 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilatio...

Page 27: ...You may have further questions about installation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and seri...

Page 28: ...WIRING DIAGRAM Black Connectors Receiver To Thermopile White Red CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous opera tion Verify...

Page 29: ...8 1b 1d 1a 1c 1e 26 17 Cat No Model Description F2506 Westerly32ZMN 32 with ProFlame Remote Millivolt NG F2507 Westerly32ZMP 32 with ProFlame Remote Millivolt LP WARNING Failure to position the parts...

Page 30: ...0 38 4 10 J8046 Painted Base Assembly 1 11 J1961 Screw 10 32 x 0 38 4 12 Firebox Bottom 1 13 J1989 Bushing 1 14 J3564 Elbow Male 1 15 J8047 Valve Bracket 1 16 K2005 Gas Valve Remote 1 J4600 Gas Valve...

Page 31: ...AND WESTERLY32ZMP 4 11 14 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved wit...

Page 32: ...J8050 Top Front Louver 1 7 J3709 Firebox Hood 1 8 Firebox Support 2 9 J3629 Shoulder Screw 4 10 Firebox Top 1 11 J3706 Outer Base 1 12 Firebox Wrapper 1 13 J8051 Cover 1 14 J1955 Hex Screw 10 16 x 0 3...

Page 33: ...RY KIT Manual variable control and automatic thermostat variable control A blower will increase air flow to assist heat distribution from the firebox F1086 GA3750A Manual Fan Variable Speed DUPLEX OUT...

Page 34: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___...

Page 35: ...cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructi...

Page 36: ...lt your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 900568 00 Rev E 03 2020 1769 East Lawrence Street Russellville AL 35654 ComfortFlame us co...

Reviews: