3_SEQUENCE OF COMMANDS FOR MACHINE START-UP
S
TART
-
UP SITUATION WITH MACHINE OFF
To start work, starting with a situation with the machine off, you need to:
•
rotate the protection differential switch to the ON position, coordinated with the main earthing system,
placed upstream of the machine in the user's system.
•
rotate the timer knob to the ON position (to the left) for the continuous cycle, or in the opposite position
(to the right), and select the work minutes desired for the timed cycle.
•
press Button 1 that activates rotation of the bowl and the spiral.
S
TART
-
UP SITUATION WITH MACHINE POWERED
To re-start work, following suspension of the work, press button 1 having restored the safety present.
S
TART
-
UP SITUATION WITH MACHINE IN EMERGENCY MODE
(
EXAMPLE THERMAL PROTECTION TRIPPED
)
•
switch off the machine, with the sequence of commands indicated in
point 05.04
;
•
leave the electric motor to cool for approx. half an hour;
•
start the machine, with the sequence indicated in
point 05.03
– section “
START WITH MACHINE OFF
”.
4_COMMANDS SEQUENCE FOR MACHINE SWITCH OFF
For total machine switch off, from the work terminated or shut-off condition, you need to:
•
Press Button 0 that terminates rotation of the bowl and the spiral.
•
Rotate the knob on the timer in position 0.
•
Rotate the protection differential switch to the OFF position, coordinated with the main earthing system,
placed upstream of the machine in the user's system, which disconnects the machine from the electrical
power supply.
W
HEN THE MACHINE IS NOT ACTIVE
,
SELECT
(
SWITCH OFF
)
THE MAIN SYSTEM OF THE ELECTRICAL ENERGY MAINS AND
DISCONNECT THE CURRENT SOCKET
.
5_FUNCTIONING ANOMALIES
PROBLEM
PROBABLE CAUSES
POSSIBLE SOLUTIONS
THE MOTOR STOPS
The motor circuit breaker ("thermal
switch") identifies motor heating
Wait for approx. 30' until the motor
cools; then re-start the work
Malfunctioning and/or breakage of any
electrical part
Contact the Dealer's Authorised,
Trained Technician
IF YOU REALISE
...
PROOF
THE ELECTRIC PHASES
ARE NOT ALL ACTIVE
•
If the power supply is three-phase, the rotation speed lowers to 1/3 the
power. For each phase not active. Rotations are lost.
•
If the power supply is monophase, the phase loss leads to no electricity
supply.