GENERAL INFORMATION
3.1
INSPECTION
Please inspect the unit on receipt. If the unit is damaged, contact the carrier immediately and file a damage claim
with them. Save all packing materials when filing a claim. Freight damage claims are the responsibility of the
purchaser and are not covered under warranty.
3.2
OPERATOR MANUAL
This manual contains important information for your safety and the installation, operation, maintenance and
service of this equipment. Please read the manual carefully and ensure all operators of the equipment are aware
of the contents and safety requirements. You must also assess all hazards and risks associated with the operation
of the equipment in your environment and advise all operators of these.
3.3
INSTALLATION
This equipment must be installed by an authorized person in accordance with local codes as well as local gas,
electricity, any applicable statutory regulations and manufacturer requirements.
An approved gas shut-off valve must be installed between the main gas piping system and the appliance.
To facilitate servicing of appliance, it is advisable to install a 3/4” pipe union between gas shut-off valve and
equipment.
3.4
GAS CONNECTION
The appliance must be connected by an authorized person to the gas type specified on the unit. The gas type is
shown adjacent to the rear gas connection point and on the data plate. Connect to and use only the correct type
of gas.
3.5
GAS PRESSURE
The authorized person installing this equipment must ensure that the gas operating pressure is the same as
shown on the rating plate and that there is sufficient gas volume.
The unit and its individual shut off valve must be disconnected from the gas supply piping system during any
pressure testing of the gas supply piping system at test pressures in excess of 1/2 PSIG (3.45 kPa).
3.6
COMMISSIONING
The authorized person installing this equipment must commission the equipment - gas leakage, operational
checking, adjustments and instructing the owner on use of the equipment are prescribed requirements.
The equipment must be isolated from the gas supply piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG
(3.45 kPa).
NOTICE
Adequate means must be provided to limit the movement of the appliance without depending on the
connector and the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining means should be attached to a frame member on the back of the unit.
Summary of Contents for 7455.0900
Page 55: ...55 www combisteel com EXPLODED VIEW 7455 0905...
Page 56: ...56 www combisteel com BILL OF MATERIAL OF 7455 0905...
Page 57: ...57 www combisteel com EXPLODED VIEW 7455 0915...
Page 58: ...58 www combisteel com BILL OF MATERIAL OF 7455 0915...
Page 59: ...59 www combisteel com EXPLODED VIEW 7455 0900...
Page 60: ...60 www combisteel com BILL OF MATERIAL OF 7455 0900...
Page 61: ...61 www combisteel com EXPLODED VIEW 7455 0910...
Page 62: ...62 www combisteel com BILL OF MATERIAL OF 7455 0910...