OVEN CONTROL SETTINGS AND ADJUSTMENTS
Test Point Pressure
The oven burner pressure test point is located also on the manifold test point on the top section. The test point
pressure is shown in the Nominal Gas Consumption Table.
7.5
CONVERSION INSTRUCTIONS
TO BE COMPLETED BY AN AUTHORISED PERSON
ENSURE GAS IS ISOLATED WHILE PERFORMING CONVERSION WORK.
PERFORM A LEAK TEST BEFORE IGNITING AND CALIBRATING BURNER
AND PILOT ADJUSTMENTS.
TO PROPANE GAS
Regulator
Change regulator to PROPANE gas configuration and adjust as necessary
Open Burner/Grill Burner
Access and change the injectors to PROPANE Gas injectors
(refer Nominal Gas Consumption Table)
Oven Burner
Access and change the injector to a PROPANE Gas Injector
(refer Nominal Gas Consumption Table)
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust.
AMEND DATA PLATE AND APPLY ‘PROPANE’ GAS LABEL
TO NATURAL GAS (NG)
Regulator
Change regulator to NG gas configuration and adjust as necessary
Open Burner/Grill Burner
Access and change the injectors to a NG Injectors
(refer Nominal Gas Consumption Table)
Oven Burner
Access and change the injector to a NG Injector
(refer Nominal Gas Consumption Table)
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust
AMEND DATA PLATE AND APPLY ‘NATURAL GAS’ LABEL
SPARE PARTS
A list of major spare part items is shown at the end of this manual.
Summary of Contents for 7455.0900
Page 55: ...55 www combisteel com EXPLODED VIEW 7455 0905...
Page 56: ...56 www combisteel com BILL OF MATERIAL OF 7455 0905...
Page 57: ...57 www combisteel com EXPLODED VIEW 7455 0915...
Page 58: ...58 www combisteel com BILL OF MATERIAL OF 7455 0915...
Page 59: ...59 www combisteel com EXPLODED VIEW 7455 0900...
Page 60: ...60 www combisteel com BILL OF MATERIAL OF 7455 0900...
Page 61: ...61 www combisteel com EXPLODED VIEW 7455 0910...
Page 62: ...62 www combisteel com BILL OF MATERIAL OF 7455 0910...