9
www.combisteel.com
4. Technical Specifications
The technical specifications of capacities and electrical powers of the machines are detailed below.
Model
Kneading Cap. (kg)
Flour Cap. (kg)
Electric bowl power
(kW)
Spiral electrical
power (kW)
ISM 10-32
6
4
-
0,3 – 0,4
ISM 10-VE
6
4
-
0,37
ISM 25-32
15
10
-
0,6 – 0,9
ISM 25-VE
15
10
-
1,5
ISM 35-32
22,5
15
-
0,6 – 0,9
ISM 35-VE
22,5
15
-
1,5
ISM 50-32
30
20
-
0,75 – 1,1
ISM 50-VE
30
20
-
2,2
ISM 60-32
30
20
0
1,5 – 2,5
ISM 60-32S
30
20
0,55 kW
1,5 – 2,5
ISM 75-32
45
30
0
1,5 – 2,5
ISM 75-32S
45
30
0,55 kW
1,5 – 2,5
ISM 100-32
75
50
0
3,5-6 kW
ISM 100-32 S
75
50
0,75 kW
3,5-6 kW
ISM 200-32 S
120
80
0,75 kW
3,5-6 kW
5. Electrical Connection
The electrical connection must be carried out by authorized professionals, in accordance with the standards in
force in the country where the machine is installed. The premises must be fitted with the adequate circuit breaker
for the total load. The appliance must be fitted with a power plug for disconnection.
Before working on any electrical part of the machine, the Plug must be disconnected from the ELECTRICAL SUPPLY.
The electrical equipment that makes up the machine has been constructed in compliance with the standards in
force on Safety of Machinery - Electrical Equipment of Machines EN 60204-1. Apply the connections cable of the
machine to a retention plug, suitable for the disconnection device installed, and Plug into the socket. In line with
the operation instructions, start up the machine and check that the spiral rotates in the direction indicated by
the arrow positioned on the spiral support cover. Otherwise invert the position of the two-phase wires in the
plug: e.g., wire A to wire post B or vice versa. The machine does not require any other type of preparation and is
ready for use.