background image

MU-EOLO-1019

EOLO-330

51

 - 56

ENGLISH

10 - MAINTENANCE REGISTER

10.1

ASSISTANCE SERVICE

10.2

SCHEDULED MAINTENANCE

10.3

USING THE COMPRESSOR UNDER HEAVY-DUTY 
CONDITIONS

10.4

THE CUSTOMER CARE CENTRE

Customers continue to receive assistance after the purchase of a compressor.
To this end AEROTECNICA COLTRI has created an assistance network 
covering the entire country.

The scheduled maintenance programme is designed to keep your 
compressor in perfect working order.
Some simple tasks, described in this manual, can be carried out directly 
by the customer; others, instead, require that the work be carried out by 
trained personnel. For the latter we recommend you always contact our 
assistance network.
This section provides a simple tool with which to request assistance and 
register completed scheduled maintenance work.
Start-up and maintenance checks/tasks, once completed by our qualified 
technician, are registered in this maintenance chapter by way of an official 
stamp, signature and inspection date; the number of working hours is also 
registered.
The maintenance schedules/coupons easily let you know when our 
assistance service should be contacted to carry out work.

IMPORTANT: Our qualified technicians are at your disposal at 
any time to carry out maintenance work or repairs; we use 
only original spare parts so as to ensure quality and reliability.

Where compressors are used in particularly difficult conditions (high levels 
of pollution, presence of solid particulate in suspension etc.), scheduled 
maintenance tasks must be carried out more frequently as per the advice 
given by our assistance network.

Our qualified technicians are constantly in contact with the head offices 
of our company where there is an assistance network coordination and 
support centre, better known as the Customer Care Centre.
To contact us:

 

Telephone:  +39 030 9910301 - +39 030 9910297

 

Fax:  +39 030 9910283

 

http: www.coltri.com

 

e-mail: [email protected]

ESPAÑOL

10 - REGISTRO DE LOS MANTENIMIENTOS

10.1

SERVICIO DE ASISTENCIA

10.2

INTERVENCIONES DE MANTENIMIENTO PROGRAMADO

10.3

USO DEL COMPRESOR EN CONDICIONES 
DIFÍCILES

10.4

EL CUSTOMER CARE CENTRE

El cliente también recibe asistencia post-venta.
A tal fin AEROTECNICA COLTRI ha creado una red de asistencia que cubre 
todo el territorio internacional.

El sistema de mantenimiento programado ha sido proyectado para 
mantener su compresor en perfectas condiciones.
Algunas simples operaciones, indicadas en el presente manual, pueden ser 
llevadas a cabo directamente por el cliente; otras, sin embargo, precisan 
la intervención de personal entrenado. Para estas últimas aconsejamos 
confiar siempre su compresor a nuestra red de asistencia.
Este capítulo representa un fácil instrumento para solicitar y registrar las 
intervenciones de mantenimiento rogramado efectuadas.
La puesta en servicio y los controles previstos por el plan de mantenimiento, 
una vez efectuados por nuestro colaborador cualificado, son confirmados 
aplicando un sello, la firma, la fecha de inspección y las horas de trabajo, 
siempre en este capítulo de mantenimiento programado.
Estos boletines le permitirán saber fácilmente cuándo solicitar la 
intervención de nuestra red de asistencia.

AVISO: Nuestros colaboradores calificados se encuentran a su 
disposición en todo momento para realizar el mantenimiento 
y cualquier tipo de reparación, utilizando exclusivamente 
recambios originales que garanticen la calidad y la fiabilidad.

Por lo que se refiere a compresores utilizados en condiciones ambientales 
difíciles (elevada contaminación, presencia de elementos sólidos en suspensión 
etc.) éstos deberán ser sometidos a intervenciones de mantenimiento con 
mayor frecuencia, según el consejo dado por nuestra red de asistencia.

Nuestros colaboradores cualificados están constantemente en contacto 
con la sede central de nuestra Empresa, donde está activa una unidad 
operativa de coordinación y soporte de la actividad de la red de asistencia 
denominada Customer Care Centre.
Para ponerse en contacto con nosotros:

 

Teléfono:  +39 030 9910301 - +39 030 9910297

 

Fax:  +39 030 9910283

 

http: www.coltri.com

 

e-mail: [email protected]

Summary of Contents for EOLO-330

Page 1: ...E COMPRESSOR FOR BREATHABLE AIR COMPRESSORE A BASSA PRESSIONE PER ARIA RESPIRABILE THIRD LUNG LINE EOLO 330 EM EOLO 330 ET EOLO 330 SH EOLO 330 SU USE AND MAINTENANCE MANUAL English MANUAL DE USO Y MA...

Page 2: ......

Page 3: ...ithout the refill hoses compressor lubricating oil combustion engine lubricating oil or filtration cartridge these items are supplied inside the packaging ESPA OL Apreciado cliente le agradecemos que...

Page 4: ...ositionner le compresseur l endroit choisi Voir Chap 5 S assurer que la cartouche filtrante est bien l int rieur du filtre purificateur 1 voir Chap 7 10 Contr ler le niveau d huile en cas de compresse...

Page 5: ...preliminar 7 1 2 Requisitos de formaci n de los operadores 7 1 3 Avisos para el uso 7 1 4 Premisa 8 1 5 Garant as 8 1 6 Asistencia 9 1 7 Responsabilidad 9 1 8 Uso previsto 10 1 9 Ambiente de uso prev...

Page 6: ...10 4 The Customer Care Centre 51 10 5 Scheduled maintenance registry coupons 52 ESPA OL 6 2 Controles a realizar antes de cada jornada de trabajo 31 6 2 1 Comprobaci n del nivel de aceite lubrificante...

Page 7: ...their meaning They highlight essential information ESPA OL AVISO Hace referencia a integraciones o sugerencias para un uso correcto del compresor ATENCI N Hace referencia a situaciones de peligro que...

Page 8: ...e servicio descritas en el presente manual constituyen parte integrante del suministro del compresor Dichas normas est n destinadas al operador formado expresamente para conducir este tipo de compreso...

Page 9: ...rgo del cliente en cualquier caso la garant a vence autom ticamente caso que el compresor haya sufrido intervenciones por parte de t cnicos no autorizados por AEROTECNICA COLTRI SpA El compresor que h...

Page 10: ...tellas probadas que posean el certificado correspondiente y no supere la presi n de ejercicio indicada sobre las mismas Aspire aire no sea viciado ni est contaminado Utilice el compresor en ambientes...

Page 11: ...amente el funcionamiento del aparato y sus mandos y haber le do y comprendido toda la informaci n t cnica contenida en el presente manual Se proh be utilizar el compresor en condiciones o para usos di...

Page 12: ...TIFICATION THE COMPRESSOR Low pressure compressor for breathable air Each compressor has an identification label attached to its frame Thread Tightening torque values 6 and 4 bolt torque sequence Max...

Page 13: ...sar o llevar a cabo cualquier mantenimiento sobre el compresor Debe guardarse atentamente en un lugar conocido por el usuario del compresor los responsables los encargados del transporte instalaci n u...

Page 14: ...ng 3 1 3 Emergency equipment 3 1 4 Checks and maintenance 3 2 GENERAL PRECAUTIONS ESPA OL La directiva m quinas da las siguientes definiciones ZONAPELIGROSA cualquierzonadentroy ocercadeunam quinaenla...

Page 15: ...uridad Toda operaci n de instalaci n mantenimiento ordinario y extraordinario debe llevarse a cabo con el compresor parado y sin alimentaci n el ctrica Tras haber efectuado la limpieza del compresor c...

Page 16: ...ci n de partes del compresor no expresamente autorizadas por AEROTECNICA COLTRI El uso de accesorios herramientas materiales de consumo o partes de recambio distintos a las recomendadas por el fabrica...

Page 17: ...by the compressor 5 Fire risk 6 Risk of being crushed or dragged in the transmission belt zone 7 Danger of impact abrasion with the cooling fan 8 Danger of direct contact on the part of the operator...

Page 18: ...fety info labels description Compressor on off info plate for compressors with an electric motor only Danger high voltage 3 3 SAFETY INFO LABELS LOCATION ESPA OL 3 3 1 Descripci n de las placas de seg...

Page 19: ...mpressor ESPA OL Etiqueta del sentido de rotaci n del ventilador de refrigeraci n En la primera puesta en funcionamiento de la m quina verifique que el sentido de rotaci n del ventilador de refrigerac...

Page 20: ...deben a errores de mantenimiento como falta de aceite limpieza insuficiente ineficiencia del circuito del aire comprimido da os de los tubos flexibles apretado de los tubos tornillos etc Realice esmer...

Page 21: ...team jets on the compressor 3 5 4 Keeping the compressor clean 3 5 5 Warning signs ESPA OL El mantenimiento ordinario prescrito en el presente manual debe ser llevado a cabo s lo por personal autoriza...

Page 22: ...oid ESPA OL 4 DATOS T CNICOS 4 1 1 Monobloque cig e al pistones cilindros 4 1 2 V lvulas 4 1 3 V lvula de regulaci n de la presi n 4 1 4 V lvula de seguridad 4 1 CARACTER STICAS T CNICAS Elmonobloquee...

Page 23: ...l filler cap 18 Radiator 19 Pressure switch 20 Start stop switch 21 Tank pressure gauge 22 Pressure regulator 23 Outlet pressure gauge 24 Pressure regulation valve 25 Professional use fast coupling 26...

Page 24: ...0 330 m3 h 19 8 19 8 CFM 11 6 11 6 l 4 5 4 5 dB 100 5 100 5 Kg 54 55 lb 119 121 mm 900x450x570 900x450x570 inches 35 4x17 7x22 4 35 4x17 7x22 4 ENGLISH 4 3 TECHNICAL CHARACTERISTICS Engine Petrol Engi...

Page 25: ...20 l min 330 330 m3 h 19 8 19 8 CFM 11 6 11 6 l 4 5 4 5 dB 81 7 83 Kg 55 55 lb 121 121 mm 900x450x570 900x450x570 inches 35 4x17 7x22 4 35 4x17 7x22 4 ENGLISH Capacity air tank Electric Engine Single...

Page 26: ...Non breathable air outlet 16 Non toxic hose optional 17 Breathing regulator optional ESPA OL 4 4 CIRCUITO DE PRESI N 1 Filtro de aspiraci n 2 V lvula de aspiraci n 3 V lvula de descarga 4 Radiador 5 V...

Page 27: ...pressor requires at least two workers and in any case no individual worker should lift more than 30 Kg ESPA OL El compresor est introducido en una caja de cart n colocada sobre un europallet para que...

Page 28: ...ternal combustion engines must only be installed outdoors 5 3 1 Positioning 5 3 INSTALLATION ESPA OL Coloque el compresor en el lugar previsto y compruebe que est nivelado Para las medidas del compres...

Page 29: ...o que el compresor se coloque en un lugar que no re na las caracter sticasdeventilaci nindicadasenelp rrafo5 3 1 Posicionamiento instale una extensi n para la toma de aire del exterior o de un lugar c...

Page 30: ...d therefore potentially dangerous 5 3 4 Connecting non toxic hose and breathing regulator optional ESPA OL El compresor al momento de la entrega no contiene aceite de lubricaci n El aceite se entrega...

Page 31: ...BE RUN AT THE START OF EACH WORKING DAY 6 2 1 Lubricating oil level check ESPA OL El compresor se entrega sin el cartucho filtrante el cual se suministra junto con el compresor dentro de una bolsa sel...

Page 32: ...ocumentation ESPA OL Efect e una inspecci n del tubo at xico a y compruebe que no presenta cortes orificios abrasiones p rdidas etc Si resulta necesario sustit yalo por un tubo nuevo 6 2 2 Compruebe l...

Page 33: ...e people to carbon monoxide ESPA OL Antes de la puesta en marcha descargue el aire presente dentro del compresor para evitar un arranque bajo esfuerzo desplace la palanca la llave del carburante a en...

Page 34: ...100 minutes continuous then turn off the compressor at least 30 minutes for cooling ESPA OL 6 3 2 Puesta en marcha y apagado con el motor el ctrico AVISO Estas operaciones deben ser realizadas por per...

Page 35: ...ls requiring a maximum air consumption of 330 litres a minute 330 l min ESPA OL Los compresores de la serie EOLO 330 han sido construidos para obtener aire no respirable a baja presi n para el uso pro...

Page 36: ...ped with relative regulator WARNING When diving is recommended to be provided with a source of breathable air alternative to the compressor Depth m Depth m Time of permanence min Time of permanence mi...

Page 37: ...ways make sure the cause of the emergency has been eliminated before proceeding with another refill ESPA OL Para utilizar el compresor conecte el tubo at xico a al filtro b conecte el suministrador c...

Page 38: ...das exclusivamente por el servicio de Asistencia Clientes de AEROTECNICA COLTRI o por personal calificado 7 MANTENIMIENTO PELIGRO No efect e operaciones de mantenimiento si acaba de apagar el compreso...

Page 39: ...nts Fitting hose leak Safety valve Condensate discharge ESPA OL Son aquellas operaciones de reparaci n y o sustituci n de partes mec nicas de uno o varios componentes del compresor que por norma son n...

Page 40: ...i n El motor el ctrico no arranca Falta una fase Controle los fusibles y lo condensador Potencia l nea el ctrica insuficiente Compruebe la l nea el ctrica Condensador averiado Compruebe o sustituya el...

Page 41: ...Oil table Sump capacity litres Recommended oils ESPA OL Despu s de la primera puesta en servicio es necesario proceder a la sustituci n del aceite lubricante despu s de las primeras 5 horas de uso del...

Page 42: ...l nivel del aceite debe controlarse cada 5 horas de funcionamiento del compresor El nivel del aceite debe hallarse entre el nivel m nimo y m ximo sobre el indicador del nivel del aceite a Si el nivel...

Page 43: ...rburante debe controlarse al comienzo de cada jornada laboral Para controlar el nivel del carburante desenroscar el tap n a verificarqueenelinteriordelacubetadelcarburante b hayacarburante volver a en...

Page 44: ...us danger and could cause serious damage or injury ESPA OL 7 9 DESCARGA DE LA CONDENSACI N Dentro del dep sito de aire del compresor se acumula condensaci n que debe ser descargada despu s de cada ses...

Page 45: ...ter duration work hours Filtered air volume Filter cartridge replacement frequency calculation table ESPA OL 7 10 FILTRO PURIFICADOR La sustituci n del cartucho filtrante debe realizarse a plazos calc...

Page 46: ...ti pollution standards in force Active carbon Molecular sieve Molecular sieve Active carbon Hopkalite Active carbon Molecular sieve ESPA OL Sustituci n del cartucho filtrante Para sustituir el cartuch...

Page 47: ...na vez al mes debe comprobarse el tensado de las correas La sustituci n de las correas de transmisi n debe efectuarse cada 500 horas de uso del compresor o con una periodicidad anual Verificaci n de l...

Page 48: ...rve this instruction can place staff in serious danger Be extremely careful not to crush or bend the non toxic hose ESPA OL 7 12 SUSTITUCI N DEL TUBO AT XICO Para conectar el tubo at xico c Desplace l...

Page 49: ...A LONG PERIOD ESPA OL Caso que no utilice el compresor gu rdelo en un ambiente seco protegido contra los agentes atmosf ricos y a una temperatura comprendida entre 5 C y 40 C El compresor debe coloca...

Page 50: ...ceda con la puesta fuera de servicio o el desguace del mismo Dicha operaci n debe efectuarse siguiendo las normativas vigentes 9 DESGUACE PUESTA FUERA DE SERVICIO 9 1 ELIMINACI N DE LOS DESECHOS ATENC...

Page 51: ...E LOS MANTENIMIENTOS 10 1 SERVICIO DE ASISTENCIA 10 2 INTERVENCIONESDEMANTENIMIENTOPROGRAMADO 10 3 USO DEL COMPRESOR EN CONDICIONES DIF CILES 10 4 EL CUSTOMER CARE CENTRE El cliente tambi n recibe asi...

Page 52: ...RVICE STAMP TECHNICIAN S SIGNATURE TECHNICIAN S SIGNATURE TECHNICIAN S SIGNATURE TECHNICIAN S SIGNATURE DATE DATE DATE DATE ESPA OL 10 5 BOLET N DE MANTENIMIENTO PROGRAMADO TIPO DE INTERVENCI N Y ANOT...

Page 53: ...ICE STAMP TECHNICIAN S SIGNATURE TECHNICIAN S SIGNATURE TECHNICIAN S SIGNATURE TECHNICIAN S SIGNATURE DATE DATE DATE DATE ESPA OL TIPO DE INTERVENCI N Y ANOTACIONES TIPO DE INTERVENCI N Y ANOTACIONES...

Page 54: ...54 56 EOLO 330 MU EOLO 1019 NOTES ENGLISH ESPA OL...

Page 55: ......

Page 56: ...AEROTECNICA COLTRI Spa Via Colli Storici 177 25015 DESENZANO DEL GARDA BS ITALY Tel 39 030 9910301 Fax 39 030 9910283 coltri com MU EOLO 1019...

Reviews: