High-Speed Output - PNP Configuration
The Breakout cable can be used to connect high-speed outputs with a PNP-compatible PLC input, if a pull-up resistor
(for example, 2.2 kOhms 0.5W) is connected from the output to +24VDC. In this case, the resistor supplies 24VDC to the
PLC input. The output will pull the voltage down to 0VDC, turning off the PLC input. This creates an inversion, with the
PLC input ON when the vision system output is OFF, and vice-versa. Use an external NPN to PNP converter when this
inversion is not desired. For more information, refer to
.
Figure 3-4: High-Speed Output - PNP Configuration
High-Speed Output - Relay/LED Configuration
The Breakout cable can be used to connect the high-speed outputs to a relay, LED or similar load. Connect the negative
side of the load to the output and the positive side to +24VDC. When the output switches on, the negative side of the load
is pulled down to 0VDC, and 24VDC appears across the load. Use a protection diode for a large inductive load, with the
anode connected to the output and the cathode connected to +24VDC. For more information, refer to
Figure 3-5: High-Speed Output - Relay/LED Configuration
20
Summary of Contents for In-Sight 5000 Series
Page 1: ...In Sight 5000 Series Vision System InstallationManual...
Page 2: ......
Page 4: ...ii...
Page 8: ...vi...
Page 10: ...viii...
Page 12: ...x...
Page 20: ...8...
Page 41: ...Figure 3 11 5600 and 5603 Vision System Dimensions Without Lens Cover Specifications 29...
Page 43: ...Figure 3 13 5604 and 5605 Vision System Dimensions Without Lens Cover Specifications 31...
Page 44: ...32...
Page 46: ...34...
Page 47: ......
Page 48: ...P N INS 597 0027 07 Rev B...