Model 1450 I/O Expansion Module Installation & Reference
6. Insert wire leads from a 24VDC supply for the +24V power and ground into the 2-pin
terminal plug labeled “Power Input” on the Expansion Module (Figure 2-4).
CAUTION
Never connect the I/O Expansion Module to a power source other than 24VDC. Any other voltage
creates a risk of fire or shock and can damage the hardware. Do not connect the 24VDC source to
any terminals other than the two-pin 24VDC power connector.
Figure 2-4: Conn24VDC and Ground Wires
7. Switch on the 24VDC supply. The power LED on the In-Sight sensor and the orange
+24V LED on the Expansion Module will indicate that the sensor and Expansion Module
are receiving power.
NOTE
If you experience intermittent serial communication faults when using the 40-foot Expansion Module Cable
(P/N 300-0341-40), replace the 40-foot cable with the 15-foot cable. If problems still occur, please contact
Cognex Technical Support.
7