2 Installation
In this section…
2.1
Connecting the I/O Expansion Module ..........................5
2.2 Configuring
the
In-Sight Sensor.....................................8
2.1 Connecting the I/O Expansion Module
To connect an I/O Expansion Module to the In-Sight sensor:
1. Verify that the 24VDC power supply is switched off.
2. Connect the power and ground wires from remote I/O devices to terminals on the
I/O Expansion Module.
Figure 2-1: Connecting I/O Wires
a. Use a flat-head screwdriver to loosen the screw terminals.
b. Insert wire leads from remote I/O devices into the appropriate positions on the
terminal block. Refer to Section 3.4.3: Terminal Block Assignments on page 19 to
verify the assigned signal at each position.
NOTE
The I/O Expansion Module outputs labeled HSOUT0 and HSOUT1 correspond to the In-Sight
1000 series/3400/4000 series/5000 series sensor’s built-in outputs. These signals pass thru the micro-
controller on the I/O Expansion Module without processing. In contrast, the general-purpose outputs
labeled OUT0 through OUT7 are lower speed because the micro controller processes these signals before
they are transmitted to remote devices.