Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
10
To connect the Breakout Module to the In-Sight 1000:
1
Verify the 24VDC power supply being used is switched off.
2
Optionally, connect the power and ground wires for the acquisition trigger input and
the discrete outputs into their corresponding terminals on the Breakout Module.
3
Optionally, connect the 9-pin male D-sub connector of an RS232 serial cable into
the corresponding 9-pin female connector on the Breakout Module.
4
Plug the Breakout Module Cable’s 15-pin male D-sub connector into the
corresponding female connector on the Breakout Module.
5
Plug the RJ-45 connector of the Breakout Module Cable (P/N 300-0341-15) into the
In-Sight 1000 sensor’s breakout port. The cable’s connectors are “keyed” to the
notch in the Breakout port.
6
Plug the wire leads from a 24VDC supply for the +24V power and ground into the
2-pin terminal plug on the Breakout Module. Alternatively, remove the terminal plug
and insert the 2-pin terminal plug attached to the In-Sight power adapter into the
keyed power adapter port on the Breakout Module (Figure 2-2).
7
Restore power to the 24V supply. The red power LED on the In-Sight 1000 and the
24V LED on the Breakout Module will indicate that the In-Sight 1000 and
Breakout Module are receiving power.