Section 2: Installing the In-Sight 1000
Installing In-Sight™ 1000 Series Vision Sensors
12
To connect an I/O Expansion Module to the In-Sight 1000:
1
Verify the 24VDC power supply being used is switched off.
2
Optionally, connect the power and ground wires for the acquisition trigger input,
discrete outputs, and discrete inputs into their corresponding terminals on the
Expansion Module.
NOTE
The outputs labeled HSOUT0 and HSOUT1 are high-speed outputs direct from the In-Sight 1000
and pass through the Expansion Module. The outputs labeled OUT0 through OUT7 are lower
speed because their signals are processed by the Expansion Module processor before being
sent to remote devices.
3
Optionally, connect the 9-pin male D-sub connector of an RS232 serial cable into
the corresponding 9-pin female connector on the Expansion Module.
4
Plug the Expansion Module Cable’s 15-pin male D-sub connector into the
corresponding female connector on the Expansion Module.
5
Plug the RJ-45 connector of the Expansion Module Cable (P/N 300-0341-15) into
the In-Sight 1000 sensor’s breakout port. The cable’s connectors are “keyed” to the
notch in the Breakout port.
6
Plug wire leads from a 24VDC supply for the +24V power and ground into the 2-pin
terminal plug labeled “Power Input” on the Expansion Module. Alternatively,
remove the terminal plug and insert the 2-pin terminal plug attached to the In-Sight
power adapter into the keyed power adapter port on the Expansion Module ().
7
Restore power to the 24V supply. The green power LED on the 1000 and the +24V
LED on the Expansion Module will indicate that the 1000 is receiving power.