RS422
The RS422 connection (Pin 11 and 12 of the multifunction port) can be used in either of the following configurations:
l
Load user modes and sensor control (half-duplex RS422).
l
Supplying line trigger signals.
l
Synchronization of line trigger signals.
Signal Levels
The switching inputs of the multifunction port can either be used for encoder or trigger input or for loading previously
stored user modes. The signal levels are switchable for all switching inputs together via software between LLL (low-
voltage-, TTL logic) and HLL (high-voltage-, HTL logic).
l
LLL level: Low 0 V… 0.8 V, High 2.4 V… 5 V, internal pull-up 10 kOhm to 5 V
l
HLL level: Low 0 V… 3 V, High 11 V… 24 V (permitted up to 30 V), internal pull-up 10 kOhm to 24
l
Pulse duration: ≥ 5 μs
24
Installation Instructions
Summary of Contents for DS900 Series
Page 1: ...DS900 Series Displacement Sensors Reference 02 21 2018 Version 9 3 0 5...
Page 14: ...Dimensions DS910B 14 Dimensions DS910B...
Page 17: ...Dimensions DS925B 17 Dimensions DS925B...
Page 18: ...18 Dimensions DS925B...
Page 28: ...28 RS422 Synchronization...
Page 31: ...31 Measuring Field Selection...
Page 42: ...January 2018...