TTL (LLL) Level
The multifunction port can be used with any of the following configurations:
Configuration
In1
In2
In3
0
Encoder with index, positive edge works with the index
1
N
A
B
1
Encoder without index, additionally line trigger possible
2
Trigger
A
B
2
Line trigger
Trigger
3
Line trigger, load up to 4 user modes
Trigger
Mode Bit 0
Mode Bit 1
4
Load up to 8 user modes
Mode Bit 0
Mode Bit 1
Mode Bit 2
5
Transmit in time stamp
Bit 0
Bit 1
Bit 2
Note
:
l
Use a shielded cable with twisted wires.The shielded Multifunction cable (CCB-2901868-05) is
recommended. It uses an M12-12 connector with male pins, providing access to trigger and inputs.
l
If the sensor is connected to a network adapter/switch that is capable of PoE and if you also use the power
supply of the multifunction port, these two power supplies have to be galvanically isolated.
1
The encoder input counts each edge. Quadrature encoders typically output 4 edges per encoder step.
2
The encoder input counts each edge. Quadrature encoders typically output 4 edges per encoder step.