Byte Description
Bit
Description
Comment
0
Trigger
Status
0
Trigger Ready
0 = Not Ready to Accept Trigger via Fieldbus (state
when Trigger Enable is low or currently processing
trigger or soft event)
1 = Ready to Accept new Trigger via Fieldbus
1
Trigger Ack
Confirmation of receiving Trigger ON bit, stays on until
Trigger bit is low
2
Acquiring
0 = Reader Idle
1 = Reader Processing a trigger (whether it came from
photo eye or fieldbus)
3
Missed Trigger
0 = No Error
1 = Received a trigger (signal from Photo Eye or Field
bus) when an other trigger or soft event is processing.
Will reset automatically when a successful trigger could
be processed again.
4
Current Mode
0 = Setup Tool Mode
1 = Run Mode
5
Serial Error
0 = No Error; Reader is Connected
1 = No Reader connected
6
Trigger Pin 4
Current State
Copy state of input line IN 1
7
Trigger Pin 2
Current State
Copy state of input line IN 2
1
Result Status
0
Results Available
Indicates that a new set of read results are available (i.e.
the contents of the Result Data are valid). Cleared when
results are acknowledged by PLC
1
Result Ack mirror
This bit mirrors the state of the "Results Ack" bit from the
output data. This is not exactly "Result Data Valid".
When the result data is first presented, this bit will still be
"0," since it just mirrors the "Results Ack" bit from the last
output but the data is valid.
2
Result Data Buffer Overrun
3
4
5
6
7
General Fault
Indicates that a fault has occurred (currently reports V1
or V2 undervoltage)
2
Soft Event
Status
0 ... 6
Soft Event Error Code
Soft event error code from DMCC
Error code 127 - timeout
7
Command Completed or
Timed out
3
ResultCode
0 ... 7
0 - Trigger result
1 - SoftEvent Command is running
2- SoftEvent Command Complete
4
TriggerID
0..7
ID value of the next trigger to be issued. Used to match
issues triggers with corresponding result data received
later.
5
ResultID
0.7
The value of the “Trigger ID” counter when the trigger
that generated these results was issued.
6
ResultLength
0..7
Actual number of bytes contained in the “Result Data"
field
25
Getting Started
Summary of Contents for DMA-EZCCM-001
Page 1: ...DMA EZCCM 001 User Guide 2019October08 Revision 6 1 6SR1 9...
Page 2: ...2...
Page 23: ...23 Getting Started...
Page 37: ...Data blocks Data memory Input 37 Connecting...
Page 38: ...Data memory Output 38 Connecting...
Page 39: ...39 Connecting...
Page 42: ...Appendix Possible Network Structures Network Structure Example 1 42 Appendix...
Page 43: ...Network Structure Example 2 Network Structure Example 3 43 Appendix...
Page 50: ...Copyright 2019 Cognex Corporation All Rights Reserved...