To define the maximum power chain length refer to the table below:
DataMan Connection
Max. number of EZCCM in Power Chain
Single DataMan 70 Series per
DMA-EZCCM-001
16
Dual DataMan 70 Series per
DMA-EZCCM-001
10
Single DataMan 150 / 260 per
DMA-EZCCM-001
11
Dual DataMan 150 / 260 per DMA-
EZCCM-001
7
Single DataMan 300 / 470 with
HPIA per DMA-EZCCM-001
3
Dual DataMan 300 / 470 with
HPIA per DMA-EZCCM-001
1