Getting Started
The module automatically starts after the electrical wiring and connecting the supply voltage.
Setting IP Address
In the delivery state the module has the IP address 192.168.1.254. A device name has not yet been assigned. The IP
address can be set via DataMan Setup Tool, web interface, a DHCP server or PROFINET DCP. In the following example,
the IP address is set by Cognex Setup Tool.
l
Connect the DMA-EZCCM-001 to a PC via the Ethernet interface.
l
Open DataMan Setup Tool.
l
Go to Repair & Support tab and select which discovered device you want to setup
l
In the right pane configure the IP details for the device
Setup Tool Connection
Each DMA-EZCCM-001 can control two DataMan readers, which are automatically added to the list when a module is
discovered. When connecting to the device, Setup Tool tunnels through the DMA-EZCCM-001 to the DataMan reader.
CAUTION
:
The DMA-EZCCM-001 will go into “setup mode” when a Setup Tool connection is opened. In Setup
Mode the DMA-EZCCM-001 will not process any trigger requests, soft events or read results. The PLC is notified
whether the DMA-EZCCM-001 operates in “run” or “setup mode”. The DMA-EZCCM-001 switches automatically
back to run mode once Setup Tool is closed. The PLC can also prohibit a Setup Tool connection by forcing the
DMA-EZCCM-001 to run mode.
Data and control are fully complaint like it would be through a Ethernet or USB connection.
21
Getting Started
Summary of Contents for DMA-EZCCM-001
Page 1: ...DMA EZCCM 001 User Guide 2019October08 Revision 6 1 6SR1 9...
Page 2: ...2...
Page 23: ...23 Getting Started...
Page 37: ...Data blocks Data memory Input 37 Connecting...
Page 38: ...Data memory Output 38 Connecting...
Page 39: ...39 Connecting...
Page 42: ...Appendix Possible Network Structures Network Structure Example 1 42 Appendix...
Page 43: ...Network Structure Example 2 Network Structure Example 3 43 Appendix...
Page 50: ...Copyright 2019 Cognex Corporation All Rights Reserved...