background image

Congratulations on having purchased a 

coemar

product. You are assured of a projector of the highest quality, both in the

componentry used and in the technology. We reiterate our invitation for you to complete the information on the previous page
to expedite any request for service information or spares (in case of problems encountered either during, or subsequent to,
installation). This information will assist in providing prompt and accurate advice from your 

coemar

service centre.

Following the instructions and procedures outlined in this manual will ensure the maximum efficiency of this product for years
to come.

Open the packaging and ensure that no part of the equipment has suffered damage in transit. In case of damage to the equip-
ment, contact your carrier immediately by telephone or fax, following this with formal notification in writing.

packing list

Ensure the packaging contains:

Fiera

575 EB

1 instruction manual
2 U-shaped cam-locking suspension devices
2 additional lenses
1 envelope containing 2 fuses suitable for respective voltages.

The 

Fiera

575 EB

should be transported in its original packaging or in a 

coemar

approved flight case.

During transportation, the packaging should ensure that the articulated movement of the 

Fiera

575 EB 

should be blocked.

Fire prevention:

1.

Fiera

575 EB

utilises a Philips 575 MSD, 575 MSR or 575 MSR/2 lamp; the use of any other lamp is not recommended

and will null and void the fixture’s warranty.

2.

Never locate the fixture on any flammable surface.

3.

The minimum distance from any flammable materials: 0,5 m.

4.

The minimum distance from the closest illuminable surface: 2 m.

5.

Replace any blown or damaged fuses only with those of an identical value. Refer to the schematic diagram if there is any
doubt.

6.

Connect the projector to the mains power via a thermal-magnetic circuit breaker.

Preventing electric shock:

1.

High voltage is present in the internals of the unit. Isolate the projector from mains supply prior to performing any function
which involves touching the internals of the unit, including lamp replacement.

2.

For mains connection, adhere strictly to the guidelines outlined in section 7 of this manual.

3.

The level of technology inherent in the 

Fiera

575 EB 

necessitates the use of specialist personnel for all service applica-

tions; refer all work to your authorised 

coemar

service centre.

4.

A good earth connection is essential for proper functioning of the projector.

Never operate the unit without proper earth connection.

5.

Do not locate the fixture in an exposed position, or in areas of extreme humidity. A steady supply of circulating air is essen-
tial.

Protection against ultraviolet radiation:

1.

Never turn on the lamp if any of the lenses, filters, or the housing is damaged; their respective functions will only operate effi-
ciently if they are in perfect working order.
Never look directly into the lamp when it is operating.

Safety:

1.

The projector should always be installed with bolts, clamps, and other fixings which are suitably rated to support the weight of
the unit.

2.

Always use a secondary safety chain of a suitable rating to sustain the weight of the unit in case of the failure of the primary
fixing point.

3.

The external surfaces of the unit at various points may exceed 150°C. Never handle the unit until at least 10 minutes have ela-
psed since the lamp was turned off.

4.

Always replace the lamp if any physical damage is evident.

5.

Never install the fixture in an enclosed area lacking sufficient air flow; the ambient temperature should not exceed 35°C.

6.

A hot lamp may explode. Always wait for at least 10 minutes to elapse after the unit has been turned off prior to attempting to
replace the lamp.
Always wear suitable hand protection when handling lamps.

Protection rating against penetration by solids and liquids:

1.

The projector is rated as an ordinary device. Its protection rating is IP 20

3. Important safety information

2. Transportation

1. Packaging

25

English

Summary of Contents for Fiera 575 EB

Page 1: ...1st edition october 2003 instructions manual 1a edizione ottobre 2003 manuale di istruzioni...

Page 2: ...massima rapidit e precisione Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your Fiera 575 EB This information will assi...

Page 3: ...4 Rapid scrolling 34 12 DMX 512 operation 35 13 Aligning the lamp in the optical path and adjusting the beam 36 14 Turning on the Fiera 575 EB without articulated movement 36 15 Resetting the counter...

Page 4: ...oltage is present in the internals of the unit Isolate the projector from mains supply prior to performing any function which involves touching the internals of the unit including lamp replacement 2 F...

Page 5: ...t risk of explosion exists if operated over their recommended lamp life We recommend therefore that the lamp be replaced within the manufacturer s specified lamp life installing the lamp 1 Using a Phi...

Page 6: ...ut refer to section 13 for a description of this procedure The projector is able to operate at 100 115 200 208 230 or 240V coemar preselects bar ring specific requests an operating voltage of 240 V Th...

Page 7: ...hould be of sufficient rating to hold the weight of the unit and should also be sufficiently rigid so as to not move or shake whilst the Fiera 575 EB moves during its operation safety chains The use o...

Page 8: ...t recent international standards namely IEC 331 IEC 332 3C CEI 20 35 NB In case of cable replacement similar cable with comparable thermal resistant qualities must be used exclusively cable 3x1 5 exte...

Page 9: ...in 2 data pin 3 data Should your DMX 512 controller utilise only XLR 5 sockets pings 4 and 5 should not be connected Ensure that all data conductors are isolated from one another and the metal housing...

Page 10: ...ach fixture Any num ber between 1 and 505 can be generated via the multifunction panel of the Fiera 575 EB This procedure must be carried out on every Fiera 575 EB When initially powered up each proje...

Page 11: ...ition of the unit if accidentally knocked out of place opto OFF LAMP lamp control Lamp on off via DMX signal or lamp always on FANS fans control Fans speed control through PCB depending on ambience te...

Page 12: ...l reading of DMX value 0 255 received by each of the 8 channels that focus take on DMX 512 line RATE DMX rate reading of DMX 512 signal value named rate HOUR working time working time in hours enter e...

Page 13: ...ill cause the display to jump to the lowest possible value associated with the respective parameter MEAS TEST o o lampeggia enter A009 enter A009 menu AOO1 FUNC CW CCW STRD ON ON OFF AA 10 589 1230 24...

Page 14: ...6 27 proportional sequencedpulseeffect slowfadedown fastfadeup Speed variable from slow to fast 69 125 27 49 step strobeoff 126 127 49 50 proportional sequencedpulseeffect fastfadedown slowfadeup Spee...

Page 15: ...flat even beam is produced with no noticeable hotspot This procedure may be useful in situations where the Fiera 575 EB may need to be switched on in an enclosed space such as in its flight case 1 Tu...

Page 16: ...rating life of the projector have not been reset An encoder system based on 4 position indicators allows the Fiera 575 EB to return to its correct position if it is accidental ly moved during operatio...

Page 17: ...tage Refer to the sticker on the transformer to ensure you are selecting the correct voltage Cables numbered 7 and 3 should under no circumstances be moved from their respective positions 3 If your op...

Page 18: ...ns of the output of the projectors to suit specific lighting applications All the lenses and diffusion filters are rotatable thus allowing adjustment of the output through 360 Beamspread circular Tran...

Page 19: ...ng the rotated position you wish it to occupy Lenses are rotatable through 360 5 After installing the new lense reposition the retaining ring and refasten the 4 screws previously loosened Attention Pr...

Page 20: ...you should find it necessary to loosen the individual barndoors to adjust their position ensure that you retighten them suf ficiently to avoid them sagging 18 2 2 Rotating the barndoors 1 The barndoo...

Page 21: ...e the performer or artist may accidentally bump the unit NOTE this device may be deactivated see section 11 Display panel functions OPTO OFF Whilst every possible precaution has been taken to ensure t...

Page 22: ...Check the sensors and all associated cabling on the wheel which is used to determine the TILT movement in the yoke SNER LINE SYNCHRONISATION Error Check and replace opto isolator U9 EPER EEPROM Error...

Page 23: ...iso coemar reserves the right to effect modifications without notification manuale istruzioni instruction manual Fiera 575 EB 1 edizione ottobre 2003 1st edition october 2003 coemar spa viaInghilterra...