background image

mounting

Fiera

575 EB

may be suspended or floor mounted.

For the purposes of floor mounting, 

Fiera

575 EB

is fitted with four pads on the base.

For suspending the fixture from lighting truss,  

coemar

has included two cam-lock devices (

A

).

The two cam-lock devices may be instal-
led in 2 diverse positions on the base of
the 

Fiera

575 EB

. These devices are

1/4 turn units. To install them, make sure
that they are correctly seated into the
appropriate slots in the base of the unit.

If the fixture is to be suspended, we recommend the use of appropriate C clamps which are capable of comfortably sustaining
the weight of the fixture. 
The C-clamps are fitted to the central shaft of the cam-lock devices.

The structure from which the unit is hung should be of sufficient rating to hold the weight of the unit and should also be sufficiently
rigid so as to not move or shake whilst the 

Fiera

575 EB

moves during its operation.

safety chains

The use of a safety chain fixed to the unit and to the primary suspension structure is
highly recommended to protect against the accidental failure, however unlikely, of
the primary suspension points.
If using an after-market safety chain not manufactured by 

coemar

, ensure that it is of

a sufficient rating to hold the weight of the unit.
The safety chain is attached by means of the two holes 

B

located in the base of the

unit as shown in the diagram.

protection against liquids

The projector contains electric and electronic components that must not come into contact with water, oil, or any liquid.

B

Attention

Always use 2 clamps to suspend the projector

Posizione 1 / Position 1

Posizione 2 / Position 2

A

A

A

6. Mechanical installation

28

English

Summary of Contents for Fiera 575 EB

Page 1: ...1st edition october 2003 instructions manual 1a edizione ottobre 2003 manuale di istruzioni...

Page 2: ...massima rapidit e precisione Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your Fiera 575 EB This information will assi...

Page 3: ...4 Rapid scrolling 34 12 DMX 512 operation 35 13 Aligning the lamp in the optical path and adjusting the beam 36 14 Turning on the Fiera 575 EB without articulated movement 36 15 Resetting the counter...

Page 4: ...oltage is present in the internals of the unit Isolate the projector from mains supply prior to performing any function which involves touching the internals of the unit including lamp replacement 2 F...

Page 5: ...t risk of explosion exists if operated over their recommended lamp life We recommend therefore that the lamp be replaced within the manufacturer s specified lamp life installing the lamp 1 Using a Phi...

Page 6: ...ut refer to section 13 for a description of this procedure The projector is able to operate at 100 115 200 208 230 or 240V coemar preselects bar ring specific requests an operating voltage of 240 V Th...

Page 7: ...hould be of sufficient rating to hold the weight of the unit and should also be sufficiently rigid so as to not move or shake whilst the Fiera 575 EB moves during its operation safety chains The use o...

Page 8: ...t recent international standards namely IEC 331 IEC 332 3C CEI 20 35 NB In case of cable replacement similar cable with comparable thermal resistant qualities must be used exclusively cable 3x1 5 exte...

Page 9: ...in 2 data pin 3 data Should your DMX 512 controller utilise only XLR 5 sockets pings 4 and 5 should not be connected Ensure that all data conductors are isolated from one another and the metal housing...

Page 10: ...ach fixture Any num ber between 1 and 505 can be generated via the multifunction panel of the Fiera 575 EB This procedure must be carried out on every Fiera 575 EB When initially powered up each proje...

Page 11: ...ition of the unit if accidentally knocked out of place opto OFF LAMP lamp control Lamp on off via DMX signal or lamp always on FANS fans control Fans speed control through PCB depending on ambience te...

Page 12: ...l reading of DMX value 0 255 received by each of the 8 channels that focus take on DMX 512 line RATE DMX rate reading of DMX 512 signal value named rate HOUR working time working time in hours enter e...

Page 13: ...ill cause the display to jump to the lowest possible value associated with the respective parameter MEAS TEST o o lampeggia enter A009 enter A009 menu AOO1 FUNC CW CCW STRD ON ON OFF AA 10 589 1230 24...

Page 14: ...6 27 proportional sequencedpulseeffect slowfadedown fastfadeup Speed variable from slow to fast 69 125 27 49 step strobeoff 126 127 49 50 proportional sequencedpulseeffect fastfadedown slowfadeup Spee...

Page 15: ...flat even beam is produced with no noticeable hotspot This procedure may be useful in situations where the Fiera 575 EB may need to be switched on in an enclosed space such as in its flight case 1 Tu...

Page 16: ...rating life of the projector have not been reset An encoder system based on 4 position indicators allows the Fiera 575 EB to return to its correct position if it is accidental ly moved during operatio...

Page 17: ...tage Refer to the sticker on the transformer to ensure you are selecting the correct voltage Cables numbered 7 and 3 should under no circumstances be moved from their respective positions 3 If your op...

Page 18: ...ns of the output of the projectors to suit specific lighting applications All the lenses and diffusion filters are rotatable thus allowing adjustment of the output through 360 Beamspread circular Tran...

Page 19: ...ng the rotated position you wish it to occupy Lenses are rotatable through 360 5 After installing the new lense reposition the retaining ring and refasten the 4 screws previously loosened Attention Pr...

Page 20: ...you should find it necessary to loosen the individual barndoors to adjust their position ensure that you retighten them suf ficiently to avoid them sagging 18 2 2 Rotating the barndoors 1 The barndoo...

Page 21: ...e the performer or artist may accidentally bump the unit NOTE this device may be deactivated see section 11 Display panel functions OPTO OFF Whilst every possible precaution has been taken to ensure t...

Page 22: ...Check the sensors and all associated cabling on the wheel which is used to determine the TILT movement in the yoke SNER LINE SYNCHRONISATION Error Check and replace opto isolator U9 EPER EEPROM Error...

Page 23: ...iso coemar reserves the right to effect modifications without notification manuale istruzioni instruction manual Fiera 575 EB 1 edizione ottobre 2003 1st edition october 2003 coemar spa viaInghilterra...

Reviews: