9. Powering up
After having followed the preceding steps, turn on the DMX 512 controller which
will be used to control the
CF 1200 H
ard
E
dge.
Following this, turn on the
power to the projector, and turn on the projector’s power switch.
The projector
will perform a reset function on all the internal and external motors.
This will last some few seconds, aftr which it will be subject to the
external signal from the controller.
DMX led
The DMX
led
will be static on to indicate that
DMX 512
signal is being correctly
received by the projector.
If the led is off, the projector is not receiving signal. check the cabling and the func-
tioning of the controller.
Fuse replacement
Locate the fuse, which protects the lamp and electronics, in the base of the
CF
1200 H
ard
E
dge
.
Using a multimeter, test the condition of the fuse, replacing it with one of equivalent
type if necessary.
function display
DMX
menu enter
+
serial number
Wa
Electronic balla
carefully before i
of the neutra
20 channels per unit
Set dmx 512 address
240V
function display
DMX
in
T 2A @ 230V
power
T 15A @ 230V
dmx 512
main setting
coemar
:
208V
230V
240V
user
:
208V
230V
240V
enter
A001
to
A493