5. Operating voltage and
coemar
factory presets (barring specific requests), a voltage of 230v and 240v
frequency
selectable via the switch on the base of the
CF 1200 H
ard
E
dge
.
Remember to switch the selector (230 or 240V) to the position which best matches
the average voltage available at your particular venue.
If your required operating voltage is 208V, you may select this internally within the
unit by moving the cable numbered 21 (currently connected in the 240V position)
or the cable numbered 22 (currently connected in the 230V position), thereby no
longer availing yourself of either the 230V or 240V option.
Incorrect voltage selection will detrimentally affect the operation of
the projector. Under no circumstance should you move the cable num-
bered 26.
CF 1200 H
ard
E
dge
is fitted with an electronic ballast which automatically stabili-
ses the output voltage to the lamp with any input voltages within the range of 180 to
260V; there is therefore no need for any electrical modifications required for dealing
with voltages within this range.
115V
208V
230V
240V
26
Bianco/White
Ner
o/black 230V
Rosso/r
ed 115 V
Blu/blue 240V
Giallo/yellow 208 V
22
21
115V
208V
230V
240V
26
Bianco/White
Ner
o/black 230V
Rosso/r
ed 115 V
Blu/blue 240V
Giallo/yellow 208 V
22
21
240V
power
main setting
coemar
:
208V
230V
240V
user
:
208V
230V
240V
220V
power
main setting
coemar
:
208V
230V
240V
user
:
208V
230V
240V