2B. MOUNTING
2B-1. Ground Mounting
The DEL AOP is shipped with the mounting brackets installed in the ground mounting position.
Adjust the position of the bracket if necessary and tighten the screws.
Mount the unit to the equipment pad through the slots provided on bracket using appropriate hardware for the mounting
surface.
2B-2. Wall Mounting
Four ¼”-20 screw holes are located on the back of enclosure for wall mounting as shown in Figure 4.
1. Remove plastic screws from back of the unit.
2. Remove mounting brackets from bottom of enclosure, re-assemble them to back of enclosure.
3. Mount unit to wall through the slots on brackets using appropriate hardware for the mounting surface.
Four 1/4in - 20
Screw Holes
for Wall Mounting
10-5/8in | 270mm
10-5
/8in | 2
70mm
Figure 4: Wall Mounting Hole Pattern
2C. PLUMBING
The DEL AOP can easily be added into the pool plumbing loop. All system components are inside the enclosure. Only the
water inlet and outlet need to be installed into the pool return line.
2C-1. Plumbing Location
• Install in the pool main return line after all other pool equipment (pump, filter, heater, and cleaner).
• The outlet must be at least 10 feet from the first return to the pool. If installing a mixing de-gas vessel (MDV), allow 10
feet from the outlet of the MDV to the first pool return.
• Use the union fittings provided to connect the DEL AOP inlet and outlet to pool plumbing as shown in Figure 5.
• For installation with additional sanitizers and pool cleaners, see Appendix A. Figures 2 & 3 show related dimensions.
Figure 5 shows a simplified plumbing diagram.