Lamp
Connector
Ballast
Wire
Connector
Lamp
Retainer
Figure 14: UV Lamp Replacement
To re-install the UV lamp:
1. Confirm power is off at the breaker.
2. Do not touch glass, as oils on your hands will damage the bulb. By holding the UV lamp white ceramic cap, slowly
press the UV lamp fully past the lamp retainer tabs and into the quartz tube until it is seated on the lamp cushion in the
bottom of the tube.
3. Connect the lamp connector to the connector on the ballast.
4. Install UV lamp access panel.
5. Reset UV indicator by pressing button on the inside door behind the Smart Status indicators. (Fig 10)
4C-2. Quartz Tube Removal and Cleaning (Every Six Months)
The UV lamps are housed in a quartz tube. If the quartz tube becomes dirty, its ability to transmit UV rays from the lamp will
be diminished. The quartz tube(s) should be removed from the UV reactor every six (6) months and cleaned if necessary.
Note: For instructions on cleaning without mechanical disassembly, see Appendix C.
Note: If the DEL AOP is installed below water level, the bypass valves must all be CLOSED to prevent excess pool water from
draining into the open unit when a quartz tube is removed.