4A-5. Injector Tube Adapter Description
This component connects the ozone gas line to the injector manifold (refer to Figure 12). When servicing this component, do
not tighten past 10 in-lbs torque or the component may be damaged.
APG2
Ozone
Modules
Orthographic View
Angle View
Air
Filter
Ozone
LED
Indicator
Air
Filter
Ozone
Gas Line
Check
Valve
Injector
Tube Adapter
Figure 11: Ozone Generator System Overview
4A-6. Ultraviolet Lamps Description
There are two lamps in each Del AOP unit. The violet UV-C light on system smart status LEDs indicates UV lamps are
operating properly (see Fig 10). If the UV lamp access panel is removed while the unit is running, the unit will be shut down
automatically. (see Fig 12). The lamps are each housed in a quartz tube that protects the lamp.
.
Panel Switch
Figure 12: Panel Switch Protection for UV Lamps