Equipment should be functionally monitored after each use and periodically. IMN will require a
control log every 12 months, and after each relevant event that occurs in the installation (bumps,
rescues, abrupt changes of environment conditions, structural modifications in the installation...)
To perform the installation inspection, read and use the following maintenance table:
MANUFACTURERS:
INSTALACIONES EN MEDIO NATURAL S.L
SARL DEHONDT CLiC-iT
Avda Mairena del Aljarafe, Nº 34-B
CP 41110 Bollullos de la Mitación, Sevilla (Spain)
5 Rue des Terres (Cellule 7)
51420 Cernay-les Reims (France)
INSTALLATION NAME:
User identification:
Name:
Adress:
Tax Number:
Model:
Serial Number:
Purchase date:
Date of first use:
GOOD
CONDITION
TO PAY
ATTENTION
INOPERATIVE
NEED
FIXING
MCD and CBS Anchor serial number readability check.
- MCD
refers to
CLiC-iT Rider Pulley
Checking of MCD wear ( Free space between
Locking Part
and
Plate
> 7,5mm)
Checking the correct operation of MCD wheels
Check that components of specified qualities are being used. And tools used are suitable
for installation.
Check the correct condition of all components before installation
Check that IMN & CLiC-IT CBS anchorages have not suffered deformations
due to shocks, deformations due to
overstress in the screw housings or in the hole where the safety cable passes.
Checking cable displacements at the beginning and end of
Double Arms
intended for ziplines.
Checking the tightness of the M10 screws in
CBS Anchors ( = 40 N*m).
Checking for cable displacement at junctions with C
able Connectors.
The lock of CLiC-iT Rider Pulley works properly when carabiner is inserted and removed
The passage of the pulley in the anchor points of IMN & CLiC-IT CBS are smooth and without relevant collisions.
There are no collisions with the structure. And the dimensional specifications described in the manual are met.
Once IMN & CLiC-IT CBS is installed, must be checked:
Corrosion check on MCD components
.
Corrosion check on every installed IMN & CLiC-IT CBS devices (Anchorages, Arms, Non Returns, etc...)
1
1
2
2
3
3
4
5
6
7
6
7
8
9
10
11
12
13
14
8
9
11
12
13
14
10
D. CONTROL AND MAINTENANCE SHEET
Summary of Contents for RiDER
Page 29: ...135º 135º 135º 135º 135º 45º 45º 90º 90º E F G H E F H G G H A F J ...
Page 30: ...135º 45º 45º 90º 90º 30º 135º 115º 115º K L G H H K J J G ...
Page 31: ...120º 60º M M M M M M N N N O M N O ...
Page 33: ...Q Other examples of park entrances and exits ...
Page 34: ...R R Zipline Other examples of park entrances and exits ...
Page 35: ...S S Other examples of park entrances and exits Zipline ...
Page 36: ...U T V Other trajectory situations ...
Page 39: ......