At the safety line terminals, both at the beginning and at the end, we
must leave at least 15 cm of free cable that leaves in excess of the
Anchor cylinder. At these two endpoints, one additional Anchor must
be installed.
At the beginning and end of the rope course should also be inspected
to check that has not suffered some kind of displacement due to an
improper screw tightening or some other defect. For such checks it is
useful to make marks on the cable to notice possible sliding.
15c
m
The ends of the safety cable must be protected by a heat shrinkable
plastic plug that fits the cable. A space of 10cm must be left from the
Anchor element to the plastic termination.
At the beginning and at the end of the rope course, a device Non Return
must be placed in the opposite direction to stop the MCD.
10cm
10cm
In situations where the safety cable has a large curve, the
Positioners is used to provide stability to the trajectory.
In tree installations an
Vertical Positioner
should be used 10cm
approximately above the arms to properly guide the safety cable.
Summary of Contents for RiDER