91c_LCD en bedingt.fm, 10.09.2010
P1890E/EN 2010-08
37
LCD display
7
The servo has overheated.
➔
Switch the tool off for a time so that it can cool down.
➔
Increase the cycle time, reduce the fastening time or the torque.
The tool motor has overheated.
➔
Switch the tool off for a time so that the motor can cool down.
➔
Increase the cycle time, reduce the fastening time or the torque.
Operating voltage is outside the admissible range.
➔
Change the battery. If this does not help:
➔
Return tool to
Sales & Service Centers
for repair.
Current at servo output stage is too high.
There may be a short circuit.
➔
Return tool to
Sales & Service Centers
for repair.
Tool angle encoder is sending incorrect signals to the servo amplifier.
➔
Return tool to
Sales & Service Centers
for repair.
Warns that battery is running low.
➔
Recharge battery or replace it with one that is already charged.
Servo firmware is not compatible with measuring board software.
➔
Update servo firmware.
The rundown counter could not be read or written to.
➔
Return tool to
Sales & Service Centers
for repair.
Tool memory could not be read.
➔
Return tool to
Sales & Service Centers
for repair.
Two-stage start button defective.
➔
Return tool to
Sales & Service Centers
for repair.
Servo
Error
Temp >
Servo
Error
TempM>
Servo
Error
Voltag
Servo
Error
Curr>
Servo
Error
Angle
Low
voltag
warnin
Servo
Error
Ande80
Tool
Error
Counte
Tool
Error
Ident
Tool
Error
Start
Summary of Contents for 17BP B
Page 4: ...4 P1890E EN 2010 08 90a_ Deckblatt en fm 10 09 2010...
Page 20: ...20 P1890E EN 2010 08 91b_1_5 en bedingt fm 10 09 2010 First Operation 6...
Page 48: ...48 P1890E EN 2010 08 91e_Trouble shooting en bedingt fm 10 09 2010 Troubleshooting 9...
Page 54: ...54 P1890E EN 2010 08 90e_Ersatzteile en fm 10 09 2010 Spare parts 10...