CLEARSPAN
™
POLY BUILDINGS
52
Revision date: 05.20.20
28
GATHERING DOOR INSTALLATION: PREPARE
AND INSTALL 1.90" DOOR CONDUITS
Required parts:
• 190P200 (1.90 conduit–1.90 x 200")
Complete these steps:
1. With the door panel attached and covering the
door opening, locate the 190P0200 conduits for
the door panel.
2. Take one conduit, measure 1" in from each end
and drill a 5/16" hole through the conduit for the
cable. See Diagram A.
3. Repeat the step for the remaining door
conduits.
4. With assistance, slide one conduit into one
pocket of the gathering door panel. Tape one
end of the conduit if needed to more easily
slide it into the pocket. Center the conduits
evenly within the pockets and rotate so the
cable holes are pointing toward the top and
bottom of the door panel.
5. Trim conduit pocket as needed to expose
conduit and continue by installing the cables.
Conduit
Winch
Top of panel secured to header.
Door Panel
Drill 5/16" hole
through conduit.
1" from end of pipe to
center of 5/16" hole
1.90" Door Conduit
Diagram A
Do not cut into door
panel. Trim only the
pocket material if
needed.
Panel as seen
from the inside.
Step 5