6
Water Pumps | Version 1.02
Intended use
- Seal all fittings with a thread sealing tape to pre-
vent leakage.
- Do not let the pump run dry for a long time.
- Only touch the pump if it has been switched off for
at least 5 minutes.
- Only dismantle the pump body with the pump
switched off and the pump chamber empty.
- Only use original spare parts and accessories to
avoid possible dangers and accident risks.
- Should it be necessary to work next to the ma-
chine, the use of ear protection (headphones, ear-
muffs, etc.) is required.
2.6 Safety labels on the water pump
The following safety labels and instructions are attached
to the Water pump (Fig. 1) and must be observed.
Fig. 1: Safety labels
If safety labels on the machine are damaged or missing,
this can cause errors, personal injury and material dam-
age. The safety symbols attached to the machine must
not be removed. Damaged safety symbols must be re-
placed immediately.
As soon as the signs are not clearly visible and compre-
hensible at first glance, the machine must be stopped
until new signs have been attached.
3
Intended use
The submersible pumps SCWP 7514, SCWP 10013 and
the submersible pressure pump SPWP 1107 are suita-
ble for pumping clean water.
ATTENTION!
If the ambient temperature is lower than 4 ° C or the
pump is not used for a long time, drain the piping
system to prevent ice from forming in the pump
chamber.
ATTENTION!
Place the cable so that it can not be sucked into the
pump.
ATTENTION!
Store the device taking into account its weight, viz.
on a firm, level surface and only in a closed room
without moisture.
ATTENTION!
The pumped liquid can be hot and under high pres-
sure. Before moving or dismantling, drain the fluids in
the pump and piping to prevent scalding.
ATTENTION!
The water pump is not used for drinking water sup-
ply or for pumping food.
ATTENTION!
Do not pump salt water with the pump!
ATTENTION!
After the device has been tipped over, it is recom-
mended to set it up again and then switch it off.
ATTENTION!
Check that the supply voltage of the water pump
matches the technical data label of the water pump.
Failure to comply with these rules may result in fire,
personal injury or even death.
ATTENTION!
The pump is not suitable for pumping salt water, fae-
ces, flammable, corrosive, explosive or other haz-
ardous liquids. The delivery fluid must not exceed or
fall short of the maximum or minimum temperature
specified in the technical data.
ATTENTION!
When pumping contaminated liquids, install a suc-
tion strainer to protect the pump from dirt.
ATTENTION!
If water is not pumped after operating the water
pump for 5 minutes, switch off the pump, fill with
water and check for leaks.
Summary of Contents for 7520100
Page 20: ...20 Water Pumps Version 1 02 Spare parts Fig 14 Spare parts drawing 2 Model SCWP 10013...
Page 21: ...Spare parts Water Pumps Version 1 02 21 Fig 15 Spare parts drawing 3 Model SDWP 7514...
Page 22: ...22 Water Pumps Version 1 02 Spare parts Fig 16 Spare parts drawing 4 Model SDWP 10020...
Page 23: ...Spare parts Water Pumps Version 1 02 23 Fig 17 Spare parts drawing 5 Model SPWP 1107...
Page 26: ...www cleancraft de...