Water Pumps | Version 1.02

Intended use

- Seal all fittings with a thread sealing tape to pre-

vent leakage.

- Do not let the pump run dry for a long time.
- Only touch the pump if it has been switched off for 

at least 5 minutes. 

- Only dismantle the pump body with the pump 

switched off and the pump chamber empty.

- Only use original spare parts and accessories to 

avoid possible dangers and accident risks.

- Should it be necessary to work next to the ma-

chine, the use of ear protection (headphones, ear-
muffs, etc.) is required.

2.6 Safety labels on the water pump

The following safety labels and instructions are attached 
to the Water pump (Fig. 1) and must be observed.

 

Fig. 1:  Safety labels

If safety labels on the machine are damaged or missing, 
this can cause errors, personal injury and material dam-
age. The safety symbols attached to the machine must 
not be removed. Damaged safety symbols must be re-
placed immediately.

As soon as the signs are not clearly visible and compre-
hensible at first glance, the machine must be stopped 
until new signs have been attached. 

3

Intended use

The submersible pumps SCWP 7514, SCWP 10013 and 
the submersible pressure pump SPWP 1107 are suita-
ble for pumping clean water.

ATTENTION!

If the ambient temperature is lower than 4 ° C or the 
pump is not used for a long time, drain the piping 
system to prevent ice from forming in the pump 
chamber.

ATTENTION!

Place the cable so that it can not be sucked into the 
pump.

ATTENTION!

Store the device taking into account its weight, viz. 
on a firm, level surface and only in a closed room 
without moisture.

ATTENTION!

The pumped liquid can be hot and under high pres-
sure. Before moving or dismantling, drain the fluids in 
the pump and piping to prevent scalding.

ATTENTION!

The water pump is not used for drinking water sup-
ply or for pumping food.

ATTENTION!

Do not pump salt water with the pump!

ATTENTION!

After the device has been tipped over, it is recom-
mended to set it up again and then switch it off.

ATTENTION!

Check that the supply voltage of the water pump 
matches the technical data label of the water pump. 
Failure to comply with these rules may result in fire, 
personal injury or even death.

ATTENTION!

The pump is not suitable for pumping salt water, fae-
ces, flammable, corrosive, explosive or other haz-
ardous liquids. The delivery fluid must not exceed or 
fall short of the maximum or minimum temperature 
specified in the technical data. 

ATTENTION!

When pumping contaminated liquids, install a suc-
tion strainer to protect the pump from dirt.

ATTENTION!

If water is not pumped after operating the water 
pump for 5 minutes, switch off the pump, fill with 
water and check for leaks.

Summary of Contents for 7520100

Page 1: ...W ATER P UMPS Water pump SCWP 10013 Operating Instructions SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SDWP 7514 SDWP 10020 SCWP 7514 SPWP 1107 SPWP 1107...

Page 2: ...yright 3 1 2 Customer service 3 1 3 Limitation of liability 3 2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 4 2 4 Personal protective equipme...

Page 3: ...r maschinen de We are always interested in valuable experience and knowledge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limit...

Page 4: ...od this manual Furthermore she must instruct the staff in regular intervals and in form them about the hazards The operator must provide the necessary protec tive equipment to the staff and order the...

Page 5: ...the machine which are indicated in the individual paragraphs of these instructions The personal protective equipment is explained in the following paragraph 2 5 General safety regulations Please note...

Page 6: ...temperature is lower than 4 C or the pump is not used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Place the cable so that it can not be sucked in...

Page 7: ...tact with parts and high voltage direct contact or with parts that are under high voltage due to a defect in the device in direct contact 4 Type plate Fig 2 Type plate SCWP 7514 ATTENTION Any change o...

Page 8: ...e head max m 9 11 5 8 10 5 42 Flow rate l min 233 216 233 325 116 Feed pressure bar Inlet outlet threat Inlet Outlet mm 25 32 25 32 25 32 38 1 25 4 Suction height m 7 7 7 7 7 Grain size max mm 5 5 30...

Page 9: ...ed on top of each other Also no other items may be parked on it Step1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction...

Page 10: ...as those that occur in the sew ers or rainwater are pumped Because of its compact shape and good operability the electric pump can be used as a portable suction pump for gardening or other normal con...

Page 11: ...fting or mounting of a rope SPWP 1107 On certain models there is an outlet on the contact sur face between the pump body and the head cover It is a normal phenomenon for an electric pump that it re le...

Page 12: ...iderable damage It is therefore essen tial to seal the threaded parts of the cables with each other and the connection to the pump with Teflon tape Only the use of sealing material such as Teflon tape...

Page 13: ...l connection must be equipped with a high sensitive fault current circuit breaker RCCB 30 mA ATTENTION Only use an extension cable whose cross section and rubber sheathing correspond at least to the c...

Page 14: ...the disconnected water pump Always check the supply cable for damage such as cracks or signs of aging If necessary replace the cable before further use ATTENTION The replacement of a defective power c...

Page 15: ...the pump without pumping water must be avoided as lack of water will cause the pump to overheat This can lead to considerable damage to the device In addition there is very hot water in the system so...

Page 16: ...hat electrical devices contain a variety of recyclable materials as well as environmentally harmful components You contributes to that these components are disposed of separately and properly In case...

Page 17: ...e pump sucks in air B The pump runs continuously A Make sure the water supply water level is high enough When submerging immerse the pump in a slight angle B Set the float switch correctly Despite the...

Page 18: ...SCWP 7514 must be ordered The stator housing has the number 38 in the spare parts drawing 1 Type of device Water pump SCWP 7514 Item number 7520100 Drawing number 1 Position number 38 The order numbe...

Page 19: ...e parts drawing In case of service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your authorised de...

Page 20: ...20 Water Pumps Version 1 02 Spare parts Fig 14 Spare parts drawing 2 Model SCWP 10013...

Page 21: ...Spare parts Water Pumps Version 1 02 21 Fig 15 Spare parts drawing 3 Model SDWP 7514...

Page 22: ...22 Water Pumps Version 1 02 Spare parts Fig 16 Spare parts drawing 4 Model SDWP 10020...

Page 23: ...Spare parts Water Pumps Version 1 02 23 Fig 17 Spare parts drawing 5 Model SPWP 1107...

Page 24: ...24 Water Pumps Version 1 02 Electrical wiring diagram 14 Electrical wiring diagram Fig 18 Electrical wiring diagram of the Model SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SPWP 1107...

Page 25: ...ex I to Council Directive 2014 30 EU Relevant EU Directives Following standards where applied EN 55014 1 2006 Al A2 Electromagnetic compatibility Requirements for household appliances electric tools a...

Page 26: ...www cleancraft de...

Reviews: