background image

Type plate

Water Pumps | Version 1.02

7

The combination submersible water pumps SDWP 7514 
and SDWP 10020 are suitable for pumping clean and 
dirty water.

The submersible water pump must not be operated in 
potentially explosive environments and the max. permis-
sible temperature of the pumped medium must not ex-
ceed 35 ° C.

Proper use also includes compliance with all information 
in this manual.

For structural and technical changes to the special Wa-
ter pump the company Stürmer Maschinen GmbH as-
sumes no liability Claims of any kind due to damage due 
to improper use are excluded.

3.1 Improper use

3.2 Residual risks

Even if all safety instructions are observed, and the ma-
chine is put to its intended use, there are still residual 
risks, which are listed below:

- Risk of injury of upper and lower limbs while equip-
ment is operating.
-  Heat build-up on components can cause burns 
and other injuries.
- Danger of fire and explosions in connection with 
the absorption of wrong liquids.
- Electrical hazards due to contact with parts and 
high voltage (direct contact) or with parts that are 
under high voltage due to a defect in the device (in-
direct contact).

4

Type plate

Fig. 2: Type plate SCWP 7514

ATTENTION!

Any change on the Water pump is prohibited. The 
change may void the warranty, cause burns and 
personal injury, even fatal for the user.     
The manufacturer will not be liable for any damage 
that the results from failure to follow these instructi-
ons or from the misuse of the equipment to objects 
or persons. 

WARNING!
Danger in case of misuse!

Misuse of the special Water pump can lead to dan-
gerous situations.

-  Only operate the special Water pump in the power 

range listed in the technical data.

-  Never bypass or override the safety devices.
-  Only operate the special Water pump in a techni-

cally perfect condition.

ATTENTION!

The pump is not suitable for pumping salt water, fae-
ces, flammable, corrosive, explosive or other dan-
gerous liquids. 
The delivery fluid must not exceed or fall short of the 
maximum or minimum temperature specified in the 
technical data. 
-  Do not soak up aggressive cleaning agents as they 

could damage the device.

-  do not absorb any materials that may damage the 

filter elements (e.g., broken glass, metal, etc.).

Summary of Contents for 7520100

Page 1: ...W ATER P UMPS Water pump SCWP 10013 Operating Instructions SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SDWP 7514 SDWP 10020 SCWP 7514 SPWP 1107 SPWP 1107...

Page 2: ...yright 3 1 2 Customer service 3 1 3 Limitation of liability 3 2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 4 2 4 Personal protective equipme...

Page 3: ...r maschinen de We are always interested in valuable experience and knowledge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limit...

Page 4: ...od this manual Furthermore she must instruct the staff in regular intervals and in form them about the hazards The operator must provide the necessary protec tive equipment to the staff and order the...

Page 5: ...the machine which are indicated in the individual paragraphs of these instructions The personal protective equipment is explained in the following paragraph 2 5 General safety regulations Please note...

Page 6: ...temperature is lower than 4 C or the pump is not used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Place the cable so that it can not be sucked in...

Page 7: ...tact with parts and high voltage direct contact or with parts that are under high voltage due to a defect in the device in direct contact 4 Type plate Fig 2 Type plate SCWP 7514 ATTENTION Any change o...

Page 8: ...e head max m 9 11 5 8 10 5 42 Flow rate l min 233 216 233 325 116 Feed pressure bar Inlet outlet threat Inlet Outlet mm 25 32 25 32 25 32 38 1 25 4 Suction height m 7 7 7 7 7 Grain size max mm 5 5 30...

Page 9: ...ed on top of each other Also no other items may be parked on it Step1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction...

Page 10: ...as those that occur in the sew ers or rainwater are pumped Because of its compact shape and good operability the electric pump can be used as a portable suction pump for gardening or other normal con...

Page 11: ...fting or mounting of a rope SPWP 1107 On certain models there is an outlet on the contact sur face between the pump body and the head cover It is a normal phenomenon for an electric pump that it re le...

Page 12: ...iderable damage It is therefore essen tial to seal the threaded parts of the cables with each other and the connection to the pump with Teflon tape Only the use of sealing material such as Teflon tape...

Page 13: ...l connection must be equipped with a high sensitive fault current circuit breaker RCCB 30 mA ATTENTION Only use an extension cable whose cross section and rubber sheathing correspond at least to the c...

Page 14: ...the disconnected water pump Always check the supply cable for damage such as cracks or signs of aging If necessary replace the cable before further use ATTENTION The replacement of a defective power c...

Page 15: ...the pump without pumping water must be avoided as lack of water will cause the pump to overheat This can lead to considerable damage to the device In addition there is very hot water in the system so...

Page 16: ...hat electrical devices contain a variety of recyclable materials as well as environmentally harmful components You contributes to that these components are disposed of separately and properly In case...

Page 17: ...e pump sucks in air B The pump runs continuously A Make sure the water supply water level is high enough When submerging immerse the pump in a slight angle B Set the float switch correctly Despite the...

Page 18: ...SCWP 7514 must be ordered The stator housing has the number 38 in the spare parts drawing 1 Type of device Water pump SCWP 7514 Item number 7520100 Drawing number 1 Position number 38 The order numbe...

Page 19: ...e parts drawing In case of service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your authorised de...

Page 20: ...20 Water Pumps Version 1 02 Spare parts Fig 14 Spare parts drawing 2 Model SCWP 10013...

Page 21: ...Spare parts Water Pumps Version 1 02 21 Fig 15 Spare parts drawing 3 Model SDWP 7514...

Page 22: ...22 Water Pumps Version 1 02 Spare parts Fig 16 Spare parts drawing 4 Model SDWP 10020...

Page 23: ...Spare parts Water Pumps Version 1 02 23 Fig 17 Spare parts drawing 5 Model SPWP 1107...

Page 24: ...24 Water Pumps Version 1 02 Electrical wiring diagram 14 Electrical wiring diagram Fig 18 Electrical wiring diagram of the Model SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SPWP 1107...

Page 25: ...ex I to Council Directive 2014 30 EU Relevant EU Directives Following standards where applied EN 55014 1 2006 Al A2 Electromagnetic compatibility Requirements for household appliances electric tools a...

Page 26: ...www cleancraft de...

Reviews: