background image

2

Water Pumps | Version 1.02

Impressum

Product identification

Water pump

Item number

SCWP 7514

7520100

SCWP 10013

7520105

SDWP 7514

7520200

SDWP 10020

7520205

SPWP 1107

7520300

Manufacturer

Stuermer Maschinen GmbH 
Dr.-Robert-Pfleger-Str. 26
D-96103 Hallstadt

Fax: 

0049 (0) 951 96555 - 55

E-Mail: [email protected]
Internet: www.cleancraft.de

Indications regarding the operating instructions

Original instructions

Edition: 05.07.2018
Version: 1.02
Language: English

Author:           SN

Copyright

Copyright © 2018 Stürmer Maschinen GmbH, Hallstadt, 
Germany.

The contents of these operating instructions are the sole 
property of the company Stürmer.

Passing on as well as copying of this document, the use 
and distribution of its content are prohibited if not explic-
itly permitted. Contraventions are liable to compensa-
tion.

Subject to technical modifications and error.

Contents

1 Introduction .............................................................3

1.1 Copyright ............................................................ 3
1.2 Customer service................................................ 3
1.3 Limitation of liability ............................................ 3

2 Safety........................................................................3

2.1 Symbol explanation ............................................ 3
2.2 Obligations of the operating company ............... 4
2.3 Requirements to staff.......................................... 4
2.4 Personal protective equipment........................... 5
2.5 General safety regulations.................................. 5
2.6 Safety labels on the water pump ........................ 6

3 Intended use ............................................................6

3.1 Improper use ...................................................... 7
3.2 Residual risks ..................................................... 7

4 Type plate.................................................................7
5 Technical Data .........................................................8
6 Transport, packaging, storage...............................8

6.1 Delivery............................................................... 8
6.2 Transport ............................................................ 8
6.3 Packaging........................................................... 9
6.4 Storage ............................................................... 9

7 Device description ..................................................9

7.1 Operation and function..................................... 10

8 Installation .............................................................12

8.1 Notes on installation ......................................... 12
8.2  Electrical connection ....................................... 12

9 Start-up...................................................................13
10 Operation .............................................................14

10.1 Starting the water pump ................................. 15

11 Care, maintenance and repair ............................15

11.1 Care by cleaning ............................................ 15
11.2 Maintenance and repair ................................. 16
11.3 Disposal, recycling of used devices .............. 16
11.4 Decommissioning........................................... 16
11.5 Waste disposal of electric equipment ............ 16
11.6 Disposal of lubricants ..................................... 16

12 Disturbances, possible causes and measures.16
13 Spare parts...........................................................18

13.1 Ordering spare parts ...................................... 18
13.2 Spare parts drawing ....................................... 19

14 Electrical wiring diagram....................................24
15 Declaration of Conformity ..................................25

Summary of Contents for 7520100

Page 1: ...W ATER P UMPS Water pump SCWP 10013 Operating Instructions SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SDWP 7514 SDWP 10020 SCWP 7514 SPWP 1107 SPWP 1107...

Page 2: ...yright 3 1 2 Customer service 3 1 3 Limitation of liability 3 2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 4 2 4 Personal protective equipme...

Page 3: ...r maschinen de We are always interested in valuable experience and knowledge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limit...

Page 4: ...od this manual Furthermore she must instruct the staff in regular intervals and in form them about the hazards The operator must provide the necessary protec tive equipment to the staff and order the...

Page 5: ...the machine which are indicated in the individual paragraphs of these instructions The personal protective equipment is explained in the following paragraph 2 5 General safety regulations Please note...

Page 6: ...temperature is lower than 4 C or the pump is not used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Place the cable so that it can not be sucked in...

Page 7: ...tact with parts and high voltage direct contact or with parts that are under high voltage due to a defect in the device in direct contact 4 Type plate Fig 2 Type plate SCWP 7514 ATTENTION Any change o...

Page 8: ...e head max m 9 11 5 8 10 5 42 Flow rate l min 233 216 233 325 116 Feed pressure bar Inlet outlet threat Inlet Outlet mm 25 32 25 32 25 32 38 1 25 4 Suction height m 7 7 7 7 7 Grain size max mm 5 5 30...

Page 9: ...ed on top of each other Also no other items may be parked on it Step1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction...

Page 10: ...as those that occur in the sew ers or rainwater are pumped Because of its compact shape and good operability the electric pump can be used as a portable suction pump for gardening or other normal con...

Page 11: ...fting or mounting of a rope SPWP 1107 On certain models there is an outlet on the contact sur face between the pump body and the head cover It is a normal phenomenon for an electric pump that it re le...

Page 12: ...iderable damage It is therefore essen tial to seal the threaded parts of the cables with each other and the connection to the pump with Teflon tape Only the use of sealing material such as Teflon tape...

Page 13: ...l connection must be equipped with a high sensitive fault current circuit breaker RCCB 30 mA ATTENTION Only use an extension cable whose cross section and rubber sheathing correspond at least to the c...

Page 14: ...the disconnected water pump Always check the supply cable for damage such as cracks or signs of aging If necessary replace the cable before further use ATTENTION The replacement of a defective power c...

Page 15: ...the pump without pumping water must be avoided as lack of water will cause the pump to overheat This can lead to considerable damage to the device In addition there is very hot water in the system so...

Page 16: ...hat electrical devices contain a variety of recyclable materials as well as environmentally harmful components You contributes to that these components are disposed of separately and properly In case...

Page 17: ...e pump sucks in air B The pump runs continuously A Make sure the water supply water level is high enough When submerging immerse the pump in a slight angle B Set the float switch correctly Despite the...

Page 18: ...SCWP 7514 must be ordered The stator housing has the number 38 in the spare parts drawing 1 Type of device Water pump SCWP 7514 Item number 7520100 Drawing number 1 Position number 38 The order numbe...

Page 19: ...e parts drawing In case of service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your authorised de...

Page 20: ...20 Water Pumps Version 1 02 Spare parts Fig 14 Spare parts drawing 2 Model SCWP 10013...

Page 21: ...Spare parts Water Pumps Version 1 02 21 Fig 15 Spare parts drawing 3 Model SDWP 7514...

Page 22: ...22 Water Pumps Version 1 02 Spare parts Fig 16 Spare parts drawing 4 Model SDWP 10020...

Page 23: ...Spare parts Water Pumps Version 1 02 23 Fig 17 Spare parts drawing 5 Model SPWP 1107...

Page 24: ...24 Water Pumps Version 1 02 Electrical wiring diagram 14 Electrical wiring diagram Fig 18 Electrical wiring diagram of the Model SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SPWP 1107...

Page 25: ...ex I to Council Directive 2014 30 EU Relevant EU Directives Following standards where applied EN 55014 1 2006 Al A2 Electromagnetic compatibility Requirements for household appliances electric tools a...

Page 26: ...www cleancraft de...